LOT 202.14 SG Feedwater Pumps Flashcards
- LOT 202.14 SG Feedwater Pumps*
- *
What do the different lights on the turning gear control panel mean?
- White Light:*
- *Turning Gear speed < 2 RPM**
- Blue Light:*
- *Turning Gear speed > 2 RPM**
- Red Light:*
- *Turning Gear Running**
- Green Light:*
- *Turning Gear Stopped**
- LOT 202.14 SG Feedwater Pumps*
- *
When does the SGFPT exhaust lead diaphragm rupture to relieve internal pressure?
5 psig
- LOT 202.14 SG Feedwater Pumps*
- *
What will auto open / close the SGFPTs drain valves?
Auto Open:
SGFPT Trip
Unit Load ↓ 25%
High Drain Pot Level
2 LP Drains ONLY
- Auto Close:*
- *Unit Load ↑ 40%**
Note:
Three drain valves / SGFPT.
- LOT 202.14 SG Feedwater Pumps*
- *
What are the SGFPT’s Latch Permissives?
High / Low Pressure Stop Valves Closed
High / Low Pressure Governor Valves Closed
Manual Speed Control set to 0 RPM
- *Turbine Speed < 4800 RPM**
- Unit 2 ONLY*
- LOT 202.14 SG Feedwater Pumps*
- *
When does the SGFPTs trip on overspeed?
- Electrical Overspeed:*
- *5730 RPM (106%)**
- Mechanical Overspeed:*
- *5940 RPM (110%)**
- 109 / - 50 RPM*
- Normal Speed: 5400 RPM
- Critical Speed: 2500 RPM
- LOT 202.14 SG Feedwater Pumps*
- *
What will auto close the SGFPT Low pressure steam non-return valve?
Main Turbine Trip
- LOT 202.14 SG Feedwater Pumps*
- *
What will trip the SGFPTs?
Bearing Oil Pressure - Low (10 psig)
Lube Oil pressure → Interface valve - Low (35 psig)
Thrust Bearing Wear (± 20 mils) [2/2]
High / Low Presure Stop valves Closed
SI
P-14
- *Mechanical Overspeed (5940 RPM) [110%]**
- +109 RPM / -50 RPM*
NPSH - Low (115 psid [3 Sec TC]) [2/2]
Vacuum - Low (14” Hg OR 3 psig)
> 20” Condenser Vacuum (14” Hg)
< 20” Condenser Vacuum (3 psig)
- *Manual (Electrical/Mechanical Overspeed)**
- Local (Both) / CP006 (Electrical ONLY)*
- *Any trip from Woodward 509**
- Electrical Overspeed (5730 RPM) [106%]*
Note:
Woodward 509 Computer/Printer located on TGB 55’
- LOT 202.14 SG Feedwater Pumps*
- *
What cools the SGFPT’s lube oil coolers?
OL-ACW
- LOT 202.14 SG Feedwater Pumps*
- *
What provides steam to the SGFPTs?
- 2% - 40%:*
- *MS Equalizing Header**
- 40% - 100%:*
- *Reheat Steam from MSR 11**
- LOT 202.14 SG Feedwater Pumps*
- *
What will auto start the SGFPT’s MOPs?
- Auto Start:*
- *Running MOP Stopped**
- *Running MOP’s Discharge Pressure < 50 psig**
- Normally 75 psig - 85 psig*
- Start Permissive:*
- *No Motor Overload**
2 MOPs/SGFPT
Note:
MOP #2 is powered from MCC 1G5. (MOP #1 is non-DG backed)
- LOT 202.14 SG Feedwater Pumps*
- *
What are the SGFPT’s speed increase permissives?
Turbine Exhaust Valve Open
Suction Valve Open
Suction Pressure > 189 psig
Turning Gear Stopped
Applicable when SGFPT’s speed < 3300 RPM
- LOT 202.14 SG Feedwater Pumps*
- *
If the SGFPTs speed is raised above 600 RPM and then speed is then reduced, what speed will trip the SGFPT?
450 RPM
Once SGFPT’s speed > 3300 RPM, cannot lower < 3300 RPM
- Note:*
- Trip Enabled when SGFPT is raised above 600 RPM OR LP GOV demand Signal > 100%.
- Trip Blocked when speed < 400 RPM AND SGFPT tripped.
- LOT 202.14 SG Feedwater Pumps*
- *
What will auto start the SGFPT’s EOPs?
Bearing Oil Pressure < 12 psig
Does not supply interface valve so SGFPT will trip.
1 EOP/SGFPT
Note:
Powered from 250VDC Swbd 1A
- LOT 202.14 SG Feedwater Pumps*
- *
What are the SGFPT’s ramp rates?
- 0 RPM - 1500 RPM:*
- *33 RPM/sec**
- 1500 RPM - 3300 RPM:*
- *100 RPM/sec**
3300 RPM - 5600 RPM:
Manual: 33 RPM/sec
SGWL Control: 50 RPM/sec MAX
- LOT 202.14 SG Feedwater Pumps*
- *
What will auto start the SGFPT’s Turning Gear?
- Auto Start:*
- *SGFPT’s Speed < 2 RPM w/ SGFPT Trip**
- Start Permissives:*
- *Low / High Pressure Stop Valves Closed**
Lube Oil Pressure > 15 psig
Thermal Overload Reset
Local Switch in “ON”
Note:
SGFPT’s Turning gear powered from MCC 1G5