LOT 202.08 Extraction Steam / MSRs Flashcards

1
Q
  • LOT 202.08 Extraction Steam / MSRs*
    • *

Where does the steam for the SGFPTs come from?

A
  • < 40%:*
  • *MS Equalizing Header**
  • > 40%:*
  • *MSR 11 Extraction Steam**
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • LOT 202.08 Extraction Steam / MSRs*
    • *

Which FW Heaters are located in the condensers?

A

FWHs 15A/B/C

FWHs 16A/B/C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • LOT 202.08 Extraction Steam / MSRs*
    • *

Where does the extraction steam go on the LP Turbine?

A
  • Turbine End:*
  • *4th Stage: FWH 14A/B**
  • *6th Stage: FWH 15A/B/C**
  • *8th Stage: FWH 16A/B/C**
  • Generator End:*
  • *2nd Stage: FWH 13A/B**
  • *6th Stage: FWH 15A/B/C**

Blowdown flash tank steam goes to FWH 13A/B.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  • LOT 202.08 Extraction Steam / MSRs*
    • *

Where are the MSR thermocouples located?

A

Crossover piping between IVs and LP Turbines

  • Used for feedback control and temperature indication on reheater temperature control panel.
  • Also indicated on CP018 recorder.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • LOT 202.08 Extraction Steam / MSRs*
    • *

Where does the extraction steam go on the HP Turbine?

A

4th Stage Extraction: FWH 11A/11B

Exhaust: DA (FWH 12)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • LOT 202.08 Extraction Steam / MSRs*
    • *

If the unit is operating for an extended period of time with one MSR out of service, what should power be maintained at?

A

> 50%

Minimizes erosion of LP Turbine’s last row of blading.