What will auto close the condensate header min flow valve (FV-7022)?
CD Header Pressure < 300 psig
Ensures 5600 gpm flow through GSS Condenser.
Note:
Indicated CD Flow on CP008
- LOT 202.10 Condensate*
- *
What cools the condensate pump bearings?
CL-ACW
- LOT 202.10 Condensate*
- *
What will a high level in FW Heaters 15/16 cause?
Closes Inlet/Outlet valve for respective string
Opens Bypass MOV
Trips associated LPHD Pump
Relays for automatic High level actuation comes from LPHD pump control power.
NO AUTO FEATURES FOR FW HTRS 13/14
Note:
Anticipated following a Rx Trip
- LOT 202.10 Condensate*
- *
What is the minimum flow required through the GSS condenser?
5600 gpm
Ensured by FV-7022
- LOT 202.10 Condensate*
- *
What is the flowpath through the condensate system?
Condensers
- *Condensate Pumps (50% Capacity)**
- Condensate Pump Seals*
- *Polishers**
- Chem Feed, MFP Seals, FW Booster Pump Seals*
- *Gland Seal Condenser**
- Exhaust Hood Spray, LP Htr Drip Pump Seals*
DA Level Control Valves (LV-7406/7406A)
FW Heaters 16 → 15 → 14 → 13
- *DA Inlet Valves (MOV-574/575)**
- Close on 89%/90% DAST Level*
DA
- LOT 202.10 Condensate*
- *
What provides seals to the condensate pumps?
- Running Pump:*
- *Condensate Pump Discharge**
- Non-Running Pump:*
- *Condenser Makeup Pumps**
Seal water returns to Condensate Seal Leakoff Tank → Seal Leakoff Tank (SLOT)
Note:
Condensate Seal Leakoff Tank - High 2 auto starts both pumps
- LOT 202.10 Condensate*
- *
What are the start permissives and trips for the condensate pumps?
- Start Permissives:*
- *Discharge Valve Closed**
- No Automatic Actions*
Recirc Valve Closed
Opens and begins modulating on pump start
Shuts when pump secures [5 sec TD]
Suction Valve Open
Adequate NPSH
- Trips:*
- *Low NPSH**
- Low D/P*
NO AUTO STARTS
Note:
Controlled from CP008
- LOT 202.10 Condensate*
- *
What powers the condensate pumps?
1F / 1G / 1J Aux Buses
- LOT 202.10 Condensate*
- *
What condenser is the hotwell level standpipe aligned to?
- Normal:*
- *Condenser 12**
- Alternate:*
- *Condenser 13**
- Auto Makeup from LV-7005 on Low Level
- Auto Divert from LV-7006 on High Level
Note:
Located on CP008
- LOT 202.10 Condensate*
- *
Where can condensate hotwell reject valve (LV-7006) send condensate to?
SMUT
Other Unit
Aux Boiler
- LOT 202.10 Condensate*
- *
What will auto open the GSS Condenser bypass valve (PDV-7020)?
GSS Condenser Inlet (MOV-084) closed
GSS Condenser Outlet (MOV-082) closed
Loss of IA / Electrical Power
- *GSS Condenser D/P > 18 psid**
- Resets at 5.5 psid*