*Logbooks Apparatus Onan Generator Flashcards
All rigs- what is the max time you should manually preheat the Onan Generator?
30 sec max
How many amps are supplied to the two receptacles on the electrical cord reel outlet box?
20 amps
When stopping the Genset, let it cool down by running at no-load for ___ to ___ minutes.
3-5 min
Onan Generator- Normal operating engine oil pressure?
28-64 psi
Onan Generator- normal engine coolant operating temperature?
160°-195°F
Onan Generator- rated kilowatt output?
7.5kw
‘00 to ‘09 Rigs:
The Onan electrical panel consists of how many circuit breakers?
12
The Onan electrical panel consists of how many circuit breakers for the ‘95 Simon?
How many for the ‘96?
10
11
‘06 ALF Onan Generator:
When the Generator Logic Control is set for AUTO, the generator will start when the house batteries are below ____ Volts and will run until the battery voltage has exceeded ____ volts for one hour.
- 1v
13. 3v
‘06 ALF Onan Generator:
Once the manual start button is pushed the Onan will crank for 5 seconds in order to start. How many starting attempts will the Onan make before a “Gen Fail” message appears on the control panel?
5
What rpm does the Onan operate at?
1800
How many amps does the Onan generator supply?
How many hertz?
31 amps
60 Hz
How many quarts of 15w-40 motor oil does the Onan generator hold?
4
All Rigs- Where are the 3 locations that you will find the controls for the Onan Generator?
- On generator itself
- In cab
- Control box in left side compartment on chassis