Legacy 500 Oxygen RKA Questions Flashcards
How many oxygen cylinders supply oxygen to both crew and passengers?
One (AOM 9-14-01)
When will the passenger oxygen masks automatically deploy with the OXYGEN knob in PAX AUTO?
If the cabin altitude exceeds
14,500 ft (± 300 ft)
(AOM 9-14-30)
What are the two capacities of oxygen bottles available?
77 ft3 or 115 ft3 (AOM 9-14-30)
Where are the oxygen system parameters and indications displayed?
• On the STATUS synoptic page (AOM 9-14-01)
What are the selections that can be toggled between on the MODE SELECTOR on the oxygen mask?
- N (normal mode),
- 100%
- EMGCY
(AOM 9-14-30)
What position must the MODE SELECTOR be set to in order to stow the oxygen mask?
100% (AOM 9-14-30)
What is the purpose of the OXYGEN SAVER PUSH-PULL BUTTON on the oxygen mask?
To allow the crew to breathe cabin air when the oxygen supply is not required
(AOM 9-14-30)
Which mode can the OXYGEN SAVER PUSH-PULL BUTTON be pulled out in?
Only in the N (normal) mode
(AOM 9-14-30)
When must the OXYGEN SAVER PUSHPULL BUTTON be manually closed?
In case of Fire or Smoke
(AOM 9-14-30)
What does the Oxygen Pressure in Green indicate?
It is in the Normal Range of operation
(AOM 9-14-30)
What does the Oxygen Pressure in White indicate?
- It is in an Advisory Operating Range
- Oxygen Dispatch Pressure charts must be references for the minimum pressure to dispatch
(AOM 9-14-30)
How many Smoke Goggles are provided?
One for each flight crew member
(AOM 9-14-40)
Can Smoke or Toxic Fumes Be Purged from the Smoke Goggles? How?
By the Vent Valve (AOM 9-14-40)
The Oxygen Mask is designed to be Donned within how many Seconds?
5
(AOM 9-14-40)
Does the Oxygen mask need to be Removed from the Stowage Box to be Tested?
No
(AOM 9-14-40)