Lec 4/5 After Midterm NOT ON FINAL Clinical Instrumentation Flashcards
Do you always need to take a RG when diagnosing?
Yes
System B:
Warm vertical condensation, temp dial, power dial, touch or continuous mode
System B tips:
0.04 - .12 (.2 increments)
Button to press to charge the System B:
store
Should System B be plugged in or unpluged before use?
unplugged
What to press after unplugging system and before using:
“use”
Temp range of System B:
200-250 C (392F to 482F)
Power of System B should be set to:
> 5 (most faculty keep it on 10)
Do System B tips need to be prefit?
yes
of secs to keep apical pressure after sinking system be to 5mm from WL:
10s
Is System B only used for downpack and not backfill?
no, both
The GP is ___ when using the OBTURA:
thermoplasticized
Obtura gauge sizes:
20, 23 (we have), 25
Temp dial for Obtura should be turned to here:
far R to get to 200C
Temp Obtura should be set to:
200C
Duration required for Obtura to heat to proper temperature:
10m
TF? Only change needle and GP pellet while Obtura machine is turned off.
F. On, cold, solidified Gp won’t move
Type of needle, insert or screw in for Obtura?
screw in
To add GP to Obtura unit:
hold release button, pull plunger out, add pellet in chamber
When to test Obuta unit to ensure GP is flowing through tip:
before pt is seated
Heat shield, System B or Obtura?
Obtura, and Calamus Dual
Angle to bend Obtura need to:
45’ w bending tool, fork like end
How to tighten Obtura needle on the way down:
circle in the center of the bending tool
Calamus Dual:
2-in-1 system, System B on L (same, but w separate tips), Obtura part on R, uses integrated needle and GP cartridge