Lec 4/5 After Midterm NOT ON FINAL Clinical Instrumentation Flashcards

1
Q

Do you always need to take a RG when diagnosing?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

System B:

A

Warm vertical condensation, temp dial, power dial, touch or continuous mode

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

System B tips:

A

0.04 - .12 (.2 increments)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Button to press to charge the System B:

A

store

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Should System B be plugged in or unpluged before use?

A

unplugged

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What to press after unplugging system and before using:

A

“use”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Temp range of System B:

A

200-250 C (392F to 482F)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Power of System B should be set to:

A

> 5 (most faculty keep it on 10)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Do System B tips need to be prefit?

A

yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

of secs to keep apical pressure after sinking system be to 5mm from WL:

A

10s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Is System B only used for downpack and not backfill?

A

no, both

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The GP is ___ when using the OBTURA:

A

thermoplasticized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Obtura gauge sizes:

A

20, 23 (we have), 25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Temp dial for Obtura should be turned to here:

A

far R to get to 200C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Temp Obtura should be set to:

A

200C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Duration required for Obtura to heat to proper temperature:

A

10m

17
Q

TF? Only change needle and GP pellet while Obtura machine is turned off.

A

F. On, cold, solidified Gp won’t move

18
Q

Type of needle, insert or screw in for Obtura?

A

screw in

19
Q

To add GP to Obtura unit:

A

hold release button, pull plunger out, add pellet in chamber

20
Q

When to test Obuta unit to ensure GP is flowing through tip:

A

before pt is seated

21
Q

Heat shield, System B or Obtura?

A

Obtura, and Calamus Dual

22
Q

Angle to bend Obtura need to:

A

45’ w bending tool, fork like end

23
Q

How to tighten Obtura needle on the way down:

A

circle in the center of the bending tool

24
Q

Calamus Dual:

A

2-in-1 system, System B on L (same, but w separate tips), Obtura part on R, uses integrated needle and GP cartridge

25
Q

How to know when the Calamus Dual is ready for use:

A

blinking light stops and remains solid

26
Q

Color light for System B in the Calamus Dual system:

A

blue

27
Q

Button to press before relplacing Gp cartirdge on Calamus Dual unit:

A

flow return, unscrew top nut, replace old cartridge w new

28
Q

Heat source in clinic for downpack:

A

controlled/ maintained temperature, System B

29
Q

Benefits of controlled flow in clinic w System B:

A

Can fuse Gp pieces uniformly, heats to optimal flowable temp of 200C