Lear 45 Electrical Flashcards
1
Q
Which generator charges the emergency battery?
A
Right engine generator
2
Q
How can you potentially restore generator operation?
A
Momentarily depress the generator switch for 1 second.
3
Q
How many components are connected directly to the emergency battery bus? What are they?
A
11 ( the circuit breakers for these items are surrounds in red on the breaker panels)
- DAU1 CH A
- DAU 2 CH A
- Stby ATT, GYRO and Lighting
- Stby Altimeter vibrator and lighting
- Styby Airspeed Lighting
- Gear Cntrl and indicator
- Pax OXY (manual deploy)
- RMU 1 PWR Secondary
- Inboard Brakes
- CKPT emer instr lights
- R Pressurization
- EMER lighting on the ground
4
Q
What items are on the EMERGENCY BATTERY L and R hot busses?
A
- Left Fire Extinguisher
- Right Fire Extinguisher
- Left FWSOV
- Right FWSOV
- APU Fire Extinguisher
5
Q
How many hot busses are in the electrical system
A
Five
- Left and Right Emergency battery hot buses
- Left and Right Hot Bus
- Rear hot bus
6
Q
How many amps/hours is the main battery?
A
38 amp hour, good for 50 minutes