IOI-4 Scram Recovery Flashcards

1
Q

State the purpose of IOI-4 Scram Recovery

A

provide directions for plant recovery following Reactor Scram.

(assumes that actions of Reactor Scram ONEP and EP 2 have been completed before entry into IOI-4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:

RPV pressure?

A

<1064.7#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:

RPV water level?

A

+11.4” to 53.5”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering
the following parameters:

suppression pool temp?

A

<95F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:

Suppression Pool water level?

A

> =18.34’ and <=18.81’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:

Drywell pressure?

A

<1.23#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:

Drywell temperature?

A

<135F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:

Containment temperature?

A

<95F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

indicate methods available for maintaining RPV pressure and level with MSIVs open

A

Bypass valves and drains for pressure

Feedwater for level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Indicate methods available for maintaining RPV pressure and level with MSIVs closed.

A

RCIC or SRVs for pressure

RCIC and RWCU blowdown for level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

State the least desirable means to control reactor pressure and why

A

SRVs are the least desirable for pressure because it adds heat to the suppression pool

How well did you know this?
1
Not at all
2
3
4
5
Perfectly