IOI-4 Scram Recovery Flashcards
State the purpose of IOI-4 Scram Recovery
provide directions for plant recovery following Reactor Scram.
(assumes that actions of Reactor Scram ONEP and EP 2 have been completed before entry into IOI-4)
Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:
RPV pressure?
<1064.7#
Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:
RPV water level?
+11.4” to 53.5”
Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering
the following parameters:
suppression pool temp?
<95F
Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:
Suppression Pool water level?
> =18.34’ and <=18.81’
Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:
Drywell pressure?
<1.23#
Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:
Drywell temperature?
<135F
Following a reactor scram, determine the conditions required to allow entry into IOI-4. Considering the following parameters:
Containment temperature?
<95F
indicate methods available for maintaining RPV pressure and level with MSIVs open
Bypass valves and drains for pressure
Feedwater for level
Indicate methods available for maintaining RPV pressure and level with MSIVs closed.
RCIC or SRVs for pressure
RCIC and RWCU blowdown for level
State the least desirable means to control reactor pressure and why
SRVs are the least desirable for pressure because it adds heat to the suppression pool