IOI Flashcards

1
Q

When does FWLC transfer to single element?

A

26% Rx power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When should FWLC to start-up level control?

A

3 mlbm/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

62.2% core flow is how many mlbm/hr?

A

70 mlbm/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When is aux cooling tower put in service?

A

before 75%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When should all heater drain pumps be pumping forward, or ensure all condensate and condensate booster pumps are running?

A

approx 70%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is max power with first stage and/or second stage MSR out of service?

A

95%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

max power with one LPFWH string and 1 first stage reheater out of service?

A

90%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What’s the max power with 1 HDP out of service?

A

88%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What’s the max power with 2 HDP out of service?

A

79%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is max power with 1 HPFWH out of service?

A

95%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is max power with 1 LPFW heater out of service?

A

90%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is max power with 1 LPFWH and 1 HPFWH out of service?

A

90%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is rated steam flow and feed flow?

A

Steam – 18.97 mlbm/hr

FW – 18.94 mlbm/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is rated core flow?

A

112.5 mlbm/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

what is max tech spec steam dome pressure?

A

< 1045 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

what is feedwater temp?

A

420 deg F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is core thermal power?

A

<= 4408 MWt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the turbine roll-up ladder?

A

240 rpm - turning gear FE01 valve closes

400 rpm - vibrations

540 rpm - shaft-lift secures

800 rpm - TG standstill secures

1650 rpm - Aux oil pump secures

1800 rpm -- Tg test
vent rps transmitters
SO temps
SCW temps
Gen H2
Gen Auxilliaries
PW
Bypass valves
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

When should the offgas adsorbers be placed in treat?

A

936 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

what should be done at 400 psig?

A

1 RFPT in service

additional condensate pump in service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

When should second RWCU pump and filter be put in service?

A

> 200 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

When should you begin warming up the SJAE?

23
Q

When should SJAE be put in service?

A

300-500 psig

24
Q

What should be done at 110 psig?

A

RWCU post pump mode

25
When should you ensure RCIC is operable?
150 psig
26
When should RCIC surveillance be performed during startup?
within 12 hours after reaching 150 psig if starting up from refueling outage
27
what should be done before 60 psig Rx pressure?
warm-up RCIC Start-up level control in service one condensate booster pump in service
28
what should RFPT speed be running at with 1 pump running and 2 pumps running?
1 RFPT -- < 5850 2 RFPT < 5800
29
what are the RFPT critical speeds?
3100-3200 rpms 3279-3379 rpms
30
When is the ECCS line break annunciation valid?
> 80% Rx power AND > 90% flow
31
Who can N/A not needed steps in the IOI?
Shift supervision ( shift manager/CRS)
32
How do you verify all rods in after a scram?
push raw data button (not by looking at all green lights)
33
what should be done if an uncoupled rod is observed?
enter CRD malfunction ONEP (05-1-02-IV-1)
34
What is the minimum Rx period?
90 seconds
35
what should be done if too short of a Rx period is observed?
Insert all control rods to increase period
36
when should you go to single notch withdrawal?
10 times initial count rate
37
What is the tech spec and admin limits for heatup/cooldown rates?
tech spec 100 deg F admin 90 deg F
38
what temp should feedwater temp be maintained at? why?
> 70 deg F, to protect the FW flued heads
39
what should drywell pressure be maintained at?
< 1 psig
40
what is Keff when Rx is exactly critical?
Keff = 1
41
What is reactor period definition?
time it takes for initial neutron population to change from some initial value to "e" (2.718) times that initial value. Period is measured is seconds.
42
What is reactor period if there is no change?
infinity
43
What is doubling time?
time taken for neutron population to double
44
RX period calculation?
RX period = DT x 1.44
45
reactor period
change in neutrons from one generation to the next
46
criticality
increase in counts with no rod motion
47
approaching criticality? (Control rods_)
use single notch control rods
48
criticality is expected when?
criticality is expected at any time after the first rod is not full in
49
M3?
required prior to mode 3 after a hydro pressure test
50
S
recommended for startup or mode 3
51
calculate period
1.44 x Doubling time
52
heatup/cooldown plots
don't exceed 90F admin and 100F TS (taken every 15 minutes)
53
Begin single notch withdrawal when?
at 10 times the initial SRM count rate