Do carbon monoxide detectors have an expiration date?
Yes
Every RV must have what?
Fire extinguisher
Within how many inches (mm) does a portable fire extinguisher need to be mounted from, the primary exit?
24 inches ( 600 mm )
What is the minimum size and type of fire extinguishers for motor homes?
Minimum 10 B:C fire extinguisher
What is the minimum size and type of fire extinguishers for towable RVs?
Minimum 5 B:C fire extinguisher
What is the minimum size and type of fire extinguishers for the cargo area of a toy hauler?
Minimum 10 B:C fire extinguisher
Every RV must have what inside of it?
Smoke detectors
Do smoke detectors have an expiration date?
Yes
Where inside the RV must a smoke detector be installed?
In the living or cooking area
The smoke detector must be…
Battery operated
A smoke detector must be installed in accordance with its…
Listing
What must every RV with a propane system have?
A propane gas detector
What must an LPG ( Liquefied petroleum gas ) be for RV use?
Listed
Do LPG detectors have an expiration date?
Yes
Every RV must have what?
A carbon monoxide detector
What are the dimensions of an alternative exit that is in the roof?
It must have a clear opening of at least 21.6” x 21.6” ( 550mm x 550mm )
They’re also must be a means of climbing down from the roof, such as a ladder
What are the dimensions of an alternative exit that is in a wall?
An alternative exit in the wall must provide an opening large enough to permit the passage of an ellipsoid ( egg shape ) with a diameter of 24” ( 610mm ) and a short axis length of 17” ( 432mm ).