Hydraulics Flashcards

1
Q

What systems are powered by the #1 HYD system?

A
  • centre AP- nose and body gear actuation and steering- left elevators- inboard TE flaps- some ailerons- alternate brakes- upper rudder (with #3)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What systems are powered by the #4 HYD system?

A
  • wing gear actuation- right elevators- outboard TE flaps- some spoilers- some ailerons- lower rudder (with #2)- normal brakes
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What systems do HYD #2 and #3 share?

A

stabilizer trim and yaw dampers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

With the loss of HYD #4, do you have auto brakes and anti-skid?

A

auto brakes- noanti-skid- yes, in pairs only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What powers the #1 and #4 demand pumps?

A

Air (it’s faster)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What powers the #2 and #3 demand pumps?

A

electric (more torque)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Is there a shut off valve for the demand pump?

A

No, theres a switch but not a valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When do demand pumps 1 and 4 automatically operate?

A

flaps in transit or out of up

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What conditions will cause the HYD SYS fault light to illuminate?

A

NAME?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What conditions will cause the demand pump low PRESS light to illuminate?

A

NAME?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When the demand pump switch is in AUX, why doesn’t the PRESS light extinguish?

A

because the pressure light is for the demand pump and it isn’t on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When do the aux hyd pumps stop operating automatically?

A

When the EDP’s pressurise the system?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

At what hyd value does the hud sus give an RF and Lo indication?

A

.75 and .35

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Can you see all the systems powered on the hyd system synoptic?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When flaps are out of up which pumps come on?

A

1/4 demand pumps operate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

With a HYD CONTROL 1 caution what may be affected with the demand pump? What must you do according to the checklist?

A

Automatic switching to turn on the demand pump and system indications may be failed.Turn on the demand pump

17
Q

If the HYQUIM fails what strange things might you see?

A

Sys fault lights flask on and off Hyd qty low messages appear/disappear Hyd qty increases and decreases

18
Q

What is required for the HYD SYS FAULT light to come on?

A

PRESS lights on both EDP and Demand