Hydraulics Flashcards
What pressurizes the hydraulic system 1 reservoir
A mechanical piston
What makes up Hydraulic system 1
Hydraulic System 1 is comprised of:
- one reservoir,
- one Engine-Driven Pump (EDP 1)
- one electric hydraulic pump
- one accumulator
What powers ACMP 1
AC BUS 2
In flight, with the selector knob set to AUTO position, when will the Hydraulic System logic activate the electric pump
- EDP or engine fail, or
* Flaps selected to any position greater than 0°.
On ground, with the selector knob set to AUTO position, when will the Hydraulic System logic activate the electric pump
• Flaps selected to any position greater than 0° and:
– Thrust levers set to takeoff thrust, or
– Ground speed greater than 50 kt.
What makes up Hydraulic System 2
Hydraulic System 2 is comprised of
- one reservoir,
- one engine-driven pump (EDP 2),
- one electric hydraulic pump,
- one accumulator and
- one PTU.
On ground, with the selector knob set to AUTO position, when will the Hydraulic System logic activate ACMP 2
Flaps selected to any position greater than 0° and: – Thrust levers set to takeoff thrust, or
– Ground speed greater than 50 kt.
Also:
– Engine 1 running and parking brake released
– During Engine 1 start (once N2 reaches 40%) if parking brake has been applied within the last 6 min.
What is the Power Transfer Unit
a hydraulic pump in Hydraulic System 2 driven by a hydraulic motor installed in Hydraulic System 1
What is the PTU used for
The PTU assists the landing gear retraction or extension, should a right engine or right EDP failure occur
When will the PTU be started automatically
The PTU will be automatically started when all the following conditions are met:
- engine 2 fails or EDP2 fails and:
– Flaps not set to zero or Landing Gear not up and locked;
– EDP 1 not fail;
– Hydraulic reservoir 2 quantity above 12%
What happens with the hydraulic system 3 when the temp reaches 100C
The HYD 3 HI TEMP caution will display
What happens if the hydraulic system 3 reaches 125C
Both electric hydraulic 3A and 3B pumps are automatically turned off
What happens if hydraulic system 3 reaches 145C
The HYD 3 OVERHEAT warning is displayed
What powers ACMP 3A
AC ESS BUS
What powers ACMP 3B
AC BUS 2