Engine company reporting to the forward staging area at a 10-76 should bring with them what equipment ?
Scba for each member
Standpipe kit with nozzle
Length of hose per fireman
Spare cylinder for each member
Ladder company reporting to the forward staging area shall bring what equipment with them?
Scba for each member
Two sets of FE tools and 6’hooks
Search and utility ropes
A spare Scba cylinder for each member
Assignment of 1st and 2nd engine at a 10-76?
Teamed to stretch the 1st line
Third and fourth engine assignment at a 10-76?
Team up and stretch the 2nd line
Responsibility and equipment of CFRD engine at a 10-76?
Assigned to fire sector supervisor
Must bring CFRD equipment and forcible entry tools
A HVAC system is in non- circulating mode when…?
Opened all outside air supply dampers.
Closed all mixing dampers.
Opened all exhaust dampers.
Location of smoke detectors in HVAC system?
At air return shaft on each floor
Location of fire dampers in HVAC system?
Where the supply ducts meet the supply shaft and wherever the duct passes through a fire partition.
Same for return air shaft.
Contents of the high rise roof kit
6 SCBA with 1hr cyl 1 bolt cutter 2 halligans 2 axes 2 search ropes 1 hydra ram (Bags for tools)
The temperature the fusible link fails at In Fire dampers in HVAC systems
50 degrees above max temp in HVAC system
Third due ladder accesses the floor above from which stairway?
A stairway other than attack stair
Who selects attack stairway?
The first due ladder officer selects a stairway with a standpipe which will provide the best attack on the fire
Who determines which stairway will be used as the evacuation stair?
Third due ladder officer
The distance manual pull stations will be from each other?
No more than 200 ft
Transmission of a pull station will?
Transmit an alarm to FD.
Visual and audible signal at the fire command station, mechanical control center, assigned location of fire safety director.
Sounding of alarm on fire floor and floor above.
Activation of smoke detector at elevator landing will?
-recall the elevators
-sound alarm on fire floor and floor above
-send alarm to FD
- alarm to fire command station, mechanical control center, assigned location of FSD
-stop air supply into and return air from floor where activated.
- activate air exhaust fans and dampers in smoke shaft or the pressurizing fans in the stairwell
-unlock the doors on the fail safe system.
( activation in the HVAC system will do all of this except recall elevators)
The fire command station has two way communication with what areas?
Floor warden stations Mechanical control center Elevators Air handling control rooms Elevator machinery rooms
The public address system can transmit to..?
All floors, elevators, and stairways either selectively or collectively
How many units are to be maintained in the forward staging area?
At least three engines and two ladders
How many spare Scba cylinders are to be maintained in the forward staging area?
20