Codes And Sub Codes Flashcards
10-25 no code
A manhole or transformer, fire or emergency
Other than described in codes 1 2 3 or 4
10-25 code 1
Fire has extended from a manhole, conduit, or transformer into a building
On what 10-25 codes will the utility company dispatch and emergency crew?
On codes 1 or 4
Code given for blocking traffic for ems unit
10-31
10-34 code 1
Defective sprinkler device or system
Defective alarm valve, broken pipe etc.
10-34 code 2
Unwarranted sprinkler alarm - not defective
Surge in pressure, people working on system, etc.
10-34 code 3
Sprinkler has been activated by heat source not associated with an accidental fire.
10-35 no code
Unwarranted alarm
( low battery condition, alarm activations without a known cause or when no condition is found warranting an emergency response)
10-35 code 1
Unnecessary alarm caused by servicing or testing
10-35 code 2
Unnecessary alarm caused by construction activities
10-35 code 3
Unnecessary alarm caused by ordinary household activities (toast, steam, aerosol spray)
10-35 code 4
Unnecessary alarm caused by other known cause. ( alarms resulting from cigarette smoking in unauthorized areas) NYFIRS report must be submitted
10-36 code 1
Vehicle accident or emergency requiring washdown
10-36 code 2
Vehicle accident, no injuries and no washdown
10-36 code 3
Vehicle accident with injuries
10-36 code 4
Vehicle accident, with or without injuries, with a trapped victim requiring extrication
10-36 no code
Vehicle emergency other than in code 1, 2, 3, or 4
10-37 code 1
Victim deceased
10-37 code 2
Victim/patient is NOT breathing and requires resuscitation or may be suffering from a serious, apparently life threatening injury or illness
10-37 code 3
Victim/ patient IS breathing and suffering from a non-serious, apparently not life threatening injury or illness
10-37 code 4
Medical assignment where the unit is 10-84, has NO patient contact and EMS is on scene
Code for a victim with thermal burns as a result of heat from a flame?
10-45 with appropriate code.
Must request response of battalion chief
10-38 code 1
Detector activation: Carbon monoxide investigation (low battery, defective detector, unwarranted alarm)
10-38 code 2
Detector activation: Carbon monoxide incident.
Meter reading of 1-9 ppm
10-38 code 3
Detector activation: Carbon monoxide emergency ( co meter reading of greater than 9 ppm)
10-38 code 4
NO Detector activation: Carbon monoxide incident or emergency (specify) e.g. No detector present, detector present but didn’t activate.
10-41 code 1
Fire marshal investigation required
Occupied structure or vehicle
Occupied at the time of fire, includes vehicles, vacant apt in occupied building, store with dwelling above, occupied detached garage, shed, or similar
10-41 code 2
Fire marshal investigation required
Unoccupied structure
A structure (commercial, residential, public) normally occupied which is unoccupied at the time of the fire
10-41 code 3
Fire marshal investigation required
Unoccupied vehicle
A vehicle, car, bus, train, with or without plates which is unoccupied at time of fire
10-41 code 4
Fire marshal investigation required
Vacant structure or structure not intended for dwelling purposes.
Vacants, build under const, sheds. Must be unoccupied at the time of the fire
Fluoroprotien foam operation
10-86
10-87
High ex foam operation
10-91
Medical emergency EMS- fire unit not required.
Only to be used for medical emergency incidents
10-92
Malicious false alarm
10-99
Unit will be operating for at least 30 mins
10-85
Fire marshal requires police assistance
10-84
Unit on scene