HF- Fuel Building HVAC Flashcards
What would close the Normal Supply AHU Isolation Dampers and Exhaust Fan Isolation dampers?
FBEVAS
A loss of Instrument Air
What provides power to the HF system electric heater control? What powers the control circuits?
NG
NK
How much air do the centrifugal fans on the HF Normal supply fans of the AHU deliver?
19,000 cfm
What normally powers the HF system fans and pumps?
NH
What is the ignition point of the charcoal beds?
625F
Why is the Fuel building maintained at a slightly negative pressure with respect to atmosphere?
To ensure that all leakage is into the building
Where do the HF Normal Exhaust fans take a suction from?
Exhaust plenums located on the Fuel Building roof
How is the air cooled in the HF system during normal operation?
Cooled utilizing evaporative cooling by the air washer which uses Domestic Water
What are the automatic functions associated with the Fuel building Normal Supply and Exhaust fans?
In Auto:
They both auto stop on a train ‘A’ or ‘B’ FBEVAS
In manual:
They automatically stop on a Train ‘A’ FBEVAS. If a Train ‘B’ FBEVAS occurs alone the fans will run dead-headed
What system serves as the essential standby power source?
DG system
What is the flowrate of the two HF Normal Exhaust fans?
21,750 cfm
What makes up the Essential AFUs?
Heater, high efficiency air filter, a high efficiency particulate air filter, a charcoal filter, and another high efficiency particulate air filter
Concerning the Essential AFU dampers that take suction from the Fuel Building and Aux Building, how are they operated and what is their fail position upon a loss of power?
Hydraulic operated and will fail closed on a loss of power
In the normal supply AHU, at what inlet air temperature will a water pump start to supply DS to the spray trees?
> 80 F
At what rate do the AFUs discharge downstream of the Normal Exhaust fans?
6000 cfm