Fuel Flashcards
In terms of basics, what is the main process that happens when turning on/off the L/R ENG run switches?
Opens/closes fuel shutoff valves(SOVs)
Scavenge ejector pumps do what?
Continuously move fuel from the main tank to the collector tank.
The fuel xfer system only operates when there is?
Fuel in the center tank.
The maximum amount of fuel that can be transferred at any given time
From ctr to wings: 400lbs
From wings to ctr: 800lbs
What causes a FUEL IMBALANCE caution message?
Imbalance between L/R tank exceeds 800lbs
With both AC boost pumps in AUTO, what would cause the Fuel Quantity Computer(FQC) to automatically start transferring fuel between main tanks?
400lbs
True or False:
Refueling can be done with battery power only?
True
Can defueling can be done with only Battery power?
No. AC power is needed.
What happens if both main ejector pumps fail with both L/R BOOST PUMP Rotary switches set to AUTO?
AC BOOST pumps automatically come on.
When the L/R BOOST PUMPS are set to AUTO, the AC boost pump will start automatically when:
- Low fuel pressure is sensed
- A fuel imbalance is sensed
- Fuel is required for the APU