FP/FD Flashcards
How are all fire detectors tested?
Automatically when A/C PWR established
or
ENG/APU/CARGO test switch on FIRE/OVHT test panel
*wheel well not tested, must be done manually with WHL WELL switch on panel
Fire detectors are located at what positions?
- ENG
- APU
- Wheel Well
APU Fire Warnings are provided at what locations?
- Flight Deck
- BELL
- Can be cancelled
- MASTER WARN
- EICAS
- DISCRETE LIGHT
- APU FIRE SWITCH
- BELL
- Nose Gear Strut
- BELL
- Can NOT be cancelled
- WARNING LIGHT
- BELL
FIRE/OVHT TEST SYS FAIL (center pedestal) switch/light illumes?
Dual loop failure has occured
*pressing switch will RESET SYS to exclude failed system
Indications of ENG FIRE?
- BELL
- MASTER WARN LIGHTS
- EICAS WARNING: ENG FIRE
- FIRE light
- FCS
- FIRE HANDLE
How are ENG FIRE HANDLES unlocked?
Electrically when fire signal detected
Manually via override switch below handle
Fire Protection available for ENG + APU (how many bottles)?
ENG = 2 bottles
APU = Single bottle
Fire Protection available for CARGO COMPARTMENTS?
3 AGENT BOTTLES
- One immediately discharges
- 30 Mins
- Other 2 at a metered rate
- 150 Mins
- 15 Additional Mins
Fire Protection available for WHEEL WELL?
None
*QRH will advise crew to lower gear
All A/C FIRE WARNINGS can be cancelled via _____ except for?
Pressing Master WARN/CAUT switch
Ground APU FIRE (wheel well)
What happens when ENG FIRE HANDLE is pulled?
- FUEL VLVs CLOSE (ENG + SPAR)
- BLD VLV CLOSES
- GEN TRIPPED
- BOTTLE ARMED
- HYD FLUID SHUT OFF TO ENG DRIVEN PUMP
What happens when APU Fire Switch pulled?
- FUEL SHUT OFF
- APU BLD VLV CLOSES
- GEN TRIPPED
- BOTTLE ARMED
L/R ENG OVHT Panel light?
Ruptured pneumatic duct in ENG Nacelle
How long is fire suppression supplied for in FWD/AFT CARGO COMPARTMENTS on ER A/C?
195 mins
via:
- BOTTLE 1 = 30 MINS
- BOTTLE 2 = 150 MINS
- BOTTLE 2A = 15 MIN
*meets 180 min ETOPS req
FWD/AFT CARGO COMPARTMENTS have how many smoke detectors?
TWO