Air Systems Flashcards
COMPT TEMP digital readout with regards to PACKS?
PACKS will target temp for coldest COMPT (zone) and use TRIM AIR to regulate heat to other two zones.
COMPT TEMP ZONE INOP light means?
S - SWITCH OFF
O - OVERHEAT (Duct)
F - FAULT (Controller)
T - TRIM AIR OFF
Selecting TRIM AIR OFF does what?
Indications? Target Temp?
TRIM AIR VLV commanded to CLOSE.
All 4 compartment TEMP INOP lights illume.
Cabin auto temp controller will attempt to maintain 75F.
RECIRC FAN purpose?
Reduce ENG BLEED AIR demand by recirculating recycled cabin air. 50% of cabin air is recirculated.
RECIRC FAN locations?
- L - Exhaust duct of FWD EE
- R - AFT Cabin
RECIRC FAN light Indications?
- ON - Operating
- INOP - OFF
- BOTH - Failure or Inhibit*
<em>*BOTH SHUT OFF w/ FWD or AFT CARGO FIRE ARMED switch pushed</em>
What happens to PACKS with RECIRC FAN OFF?
Respective PACK will operate in HI FLOW
PACK OFF Light indicates?
PACK VALVE is CLOSED
3 reasons for PACK OFF light?
- OFF
- Pack Trip (Internal Overtemp)
- Loss of air due to ENG BLD VLV closed
3 reasons for PACK INOP light?
INOP LIGHT ONLY:
- PACK OUTLET HI TEMP
- PACK AUTO TEMP CONTROLLER FAIL
INOP + PACK OFF LIGHT:
PACK OVERHEAT
PACK RESET switches reset what equip?
PACK TEMP CONTROLLER
Will PACK continue operation with HI PACK OUTLET TEMP and what are indications?
Yes, but PTC will set full cold position.
INOP light illumes.
Will PACK continue operation with internal PACK OVHT and what are indications?
No, the PACK will auto-shutdown
- INOP light illumes
- PACK valve closes
- PACK OFF light
Will PACK continue operation with AUTO TEMP CONTROLLER FAIL and what are indications?
YES, same as PACK HI OUTLET TEMP:
- PACK continues operation
- INOP light illumes.
<em>*</em><em>Unlike HI TEMP OUTLET, the pack maintains existing position to maintain temp.</em>
How can we tell if we’ve had HI PACK OUTLET TEMP vs AUTO TEMP CONTROLLER failure?
When STBY is selected:
- INOP EXTINGUISH = AUTO TEMP CONT FAIL
- *Reset is not available and manual mode is required.*
PACK STBY Switch target temperatures?
- C - 65F/18C
- N - 75F/24C
- W - 85F/29C
When will a single PACK increase airflow (HI-FLOW)?
- Opposite PACK is OFF
- Respective RECIRC FAN is OFF
- ON GROUND w/ APU or EXT AIR provided
When is PACK HI-FLOW inhibited?
- Inflight Single Engine Ops
- AFT/CARGO FIRE ARM Pressed
EE Config before start (below 7C)?
CLOSED LOOP
- INBD SUPPLY VLV OPEN
- EXHAUST VLV CLOSED
- HEAT EXCH VALVE OPEN
- BOTH FANS ON
EE Config before start (above 7C)?
OPEN LOOP - VENT OVERBOARD
- INBD SUPPLY VLV OPEN
- EXHAUST VLV OPEN
- HEAT EXCH VLV CLOSED
- BOTH FANS ON
EE Config after start?
INFLIGHT CLOSED LOOP CONFIG*
- SUPPLY VLV CLOSED
- BOTH FANS ON til Airborne
- HEAT EXCH VLV OPEN
*Allows for the cabin to pressurize.
EE VALVE light?
Any valve not in commanded position.
Select STBY–configures system to inside closed loop
IF light on after 30 sec, Overboard Exhaust Valve may be open