Fourth Year - Plumbing Level 4: BCIT Custom 2017 Flashcards
Whose recommendations should be followed for proper start-up?
A. Plumbing code.
B. Gas code[][][][][]]
C. Boiler manufacturer.
D. Homeowner[][][][][][][]]
C. Boiler manufacturer.
Which section of the manufacturer’s manual covers the distance the boiler is to be located from combustable materials?
A. Pre-installation.
B. Unpack boiler[]
C. Water piping[][]
D. Gas piping[][][]]
A. Pre-installation.
After completing the water piping in a hydronic heating system, the installer should:
A. Clock the gas meter.
B. Test the safety relief valve on the boiler.
C. Smoke-test the venting system[][][][][][][][]
D. Flush the piping to remove all impurities.
D. Flush the piping to remove all impurities.
What standard must be followed when venting the flue gases from the boiler?
A. Authority having jurisdiction.
B. Plumbing code[][][][][][][][][][][][]
C. Manufacturer’s specification.
D. Builder’s code[][][][][][][][][][][][][]
A. Authority having jurisdiction.
What can happen if a system is not properly filled?
A. Water hammer within the piping.
B. Expansion of the water in the system.
C. Air trapped in the system piping[][][][][]
D. Water will not transfer heat properly[]
C. Air trapped in the system piping.
If a gas line does not hold during a pressure-test due to a leak, what is the best way to find the leak?
A. Soapy water test.
B. A 9V flashlight[][]]
C. A propane torch[]
D. A smoke test[][][]]
A. Soapy water test.
What is the first step in servicing a boiler venting and main burner?
A. Check the vents for soot buildup.
B. Check the orifice passage[][][][][][]]
C. Check the manifold pressure[][][][]
D. Turn off the electrical and gas supplies.
D. Turn off the electrical and gas supplies.
What is the best way to clean a main burner?
A. Pressure washer.
B. Buffing wheel[][][]
C. Vacuum and soft brush.
D. Compressed air with burner in place.
C. Vacuum and soft brush.
When technicians perform continuity tests, they are checking for:
A. Opened or closed set of contacts.
B. Amperage reading[][][][][][][][][][][][][][]
C. Voltage reading[][][][][][][][][][][][][][][][][]
D. DC current[][][][][][][][][][][][][][][][][][][][][]
A. Opened or closed set of contacts.
What type of thermostat is used on a hot water heating system?
A. Dual acting thermostat only.
B. Thermostat without a heat anticipator.
C. Thermostat with a heat anticipator[][][]]
D. Digital thermostat only[][][][][][][][][][][][][][]]
B. Thermostat without a heat anticipator.
A loose wire on an aquastat may:
A. Overheat the boiler.
B. Prevent the main burner from firing.
C. Cause the main pump to stop circulating.
D. Prevent the thermostat from functioning properly.
B. Prevent the main burner from firing.
What is the main function of a LWCO on a hot water heating boiler?
A. To add water to the heating system.
B. To prevent backflow of heating system water into the potable water system.
C. To prevent the boiler main burner from starting when there is no flow[][][][][][]]
D. To prevent the boiler main burner from starting when there’s low water condition.
D. To prevent the boiler main burner from starting when there’s low water condition.
What is the procedure for testing a float-type LWCO?
A. Isolate and drain the LWCO so the main burner will shut down.
B. Isolate and drain the LWCO so the main burner will start[][][][][][]
C. Remove the wires to the LWCO[][][][][][][][][][][][][][][][][][][][][][][][][][][][]]
D. Turn off the main circulator, which causes the burner to shut down.
A. Isolate and drain the LWCO so the main burner will shut down.
What should be done if you test a 24 VAC transformer and obtain a reading of zero?
A. Replace the transformer.
B. Replace the windings on the coil.
C. Test the supply power to the transformer.
D. Check the operating aquastat[][][][][][][][][][]]
C. Test the supply power to the transformer.
A spill switch is designed to detect:
A. Products of combustion spilling out of the draft hood.
B. Water being spilled on the mechanical room floor[][][]]
C. Flame rollout from the main burner[][][][][][][][][][][][][][][][][]
D. A high concentration of carbon dioxide[][][][][][][][][][][][]]
A. Products of combustion spilling out of the draft hood.
What may untreated water cause in a hydronic heating system?
A. Water hammer within the piping.
B. Ferrous material to oxidize[][][][][]]
C. Temperature fluctuations in the system water.
D. Primary pump to surge[][][][][][][][][][][][][][][][][][][][][]]
B. Ferrous material to oxidize.
What is the main function of a zone valve in a hydronic heating system?
A. To limit the amount of feed water to the boiler.
B. To stop and start the flow of water to a circuit.
C. To prevent reverse flow of water in a zone[][][]
D. To ensure boiler water level[][][][][][][][][][][][][][][][]]
B. To stop and start the flow of water to a circuit.
What must the technician do when the zone valve drive motor fails?
A. Rebuild the drive motor.
B. Shut down and drain the system water, then replace the zone valve motor.
C. Recalibrate the zone drive motor[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]]
D. Replace the drive motor[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]]
D. Replace the drive motor.
What will happen to a non-condensing boiler when the return water temperature is too low?
A. Cool return water temperatures do not affect non-condensing boilers.
B. The boiler will overheat[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]
C. There will be unnecessary damage and boiler failure[][][][][][][][][][][][][][][]]
D. The LWCO will shut off the main burner[][][][][][][][][][][][][][][][][][][][][][][][][][][]]
C. There will be unnecessary damage and boiler failure.
What should be completed after finishing a service call?
A. Proper service and maintenance log.
B. Boiler warranty card[][][][][][][][][][][][][][][]]
C. Homeowner warranty card[][][][][][][][][]
D. Timetable sheet[][][][][][][][][][][][][][][][][][]]
A. Proper service and maintenance log.
What type of interceptor uses a baffle?
A. Solids interceptor.
B. Grease interceptor.
C. Oil interceptor[][][][]]
D. Garbage interceptor.
B. Grease interceptor.
What type of interceptor requires an orifice plate?
A. Solids interceptor.
B. Grease interceptor.
C. Oil interceptor[][][][]
D. Garbage interceptor.
B. Grease interceptor.
What type of interceptor would be required for a dental office?
A. Solids interceptor.
B. Grease interceptor.
C. Oil interceptor[][][][]
D. Garbage interceptor.
A. Solids interceptor.
What principle is used in the separation of oil or gas from wastewater?
A. Sedimentation.
B. Settlement[][][]]
C. Flotation[][][][][]]
D. Baffling[][][][][][][]
C. Flotation.
What are the three main styles of grease interceptors?
A. Oil, grease, solids.
B. Recessed, square, vented.
C. Recessed, semi-recessed, floor-mounted.
D. Floor-mounted, semi-recessed, recessed.
C. Recessed, semi-recessed, floor-mounted.
What is the chemical classification of an enzyme?
A. Activator.
B. Digester.
C. Catalyst[]
D. Cleaner[]
C. Catalyst.
To size a grease trap you would use:
A. The size of the drain.
B. The volume of the sinks.
C. The length of the drain[][]
D. The size of the garbage grinder.
B. The volume of the sinks.
For a grease interceptor to serve as a trap for a fixture it must have:
A. A removable orifice plate.
B. A cleanout on the outlet[]]
C. A cleanout on the vent[][]]
D. A 1 1/2” trap seal[][][][][][][][]]
D. A 1 1/2” trap seal.
The minimum size of vents on an oil interceptor is:
A. 1 1/4”.
B. 1 1/2”.
C. 2”[][]]
D. 2 1/2”.
A. 1 1/4”.
The proper method of disposing of grease removed from an interceptor is to:
A. Flush it down the sewer.
B. Send it to a compost facility.
C. Send it to a landfill[][][][][][][][]]
D. Send it to a rendering plant.
B. Send it to a compost facility.
Interceptors should be cleaned:
A. Once in a while.
B. Every four hours.
C. On a regular schedule.
D. When they plug[][][][][][]]
C. On a regular schedule.
What is the minimum size of an air break?
A. 1”.
B. 1 1/8”.
C. 1 1/4”.
D. 1 1/2”.
A. 1”.
What is the only fixture that may be connected either directly or indirectly to a drainage system?
A. Sterilizer.
B. Food display.
C. Bar sink[][][][][]
D. Drinking fountain.
D. Drinking fountain.
An example of clear water waste is:
A. Coffee drippings.
B. Cooling water[][][]
C. Sewage[][][][][][][][]
D. Drainage[][][][][][][]
B. Cooling water.
Which of the following fixtures may be indirectly connected to a storm drainage system?
A. Water closet.
B. Food display.
C. Dishwasher[]]
D. Drinking fountain.
D. Drinking fountain.