Fourth Year - Block H Maintenance and Repair Flashcards
Although a water distribution system contains an iron filter you still notice that there is a slight red-brown discoloration on the bathroom fixtures and the laundry. What should you do in order to fix the problem?
A. Replace the iron filter with a hand water filter.
B. Replace the zeolite and rinse with fresh water.
C. Introduce more brine into the sytem[][][][][][][][][]]
D. Backwash the filter and then regenerate the sytem with potassium permanganate.
D. Backwash the filter and then regenerate the sytem with potassium permanganate.
When installing a new cast iron tee into an existing stack, how much allowance should be made for the MJ clamps?
A. 1/4 to 1/2 inches larger than the tee.
B. 1/4 to 1/2 inches smaller than the tee.
C. 1/2 to 1 inch larger thatn the tee[][][][][]
D. Half of the size of the fitting[][][][][][][][]
A. 1/4 to 1/2 inches larger than the tee.
On a routine boiler maintenance you notice that the water in the system is clear. What would cause this to occur?
A. There is no problem as the system is running normally.
B. An automatic air vent is letting air into the system[][][][][]
C. A leak has developed on the distribution piping[][][][][][]]
D. A faulty zone valve end switch[][][][][][][][][][][][][][][][][][][][][][]
C. A leak has developed on the distribution piping.
You suspect that there is a crack in a cast iron apartment fitting. What is the easiest way to test for a crack in the fitting?
A. Get a hydrostatic pump and pump the fitting up to 200 pis. Check for leaks.[][][][]
B. Drunk the fitting into a 5 gallon pail filled with water and see if water comes out of the crack.
C. Tap the fitting very gently with a hammer[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]]
C. Tap the fitting very gently with a hammer.
The traps at the base of a 10 storey soil-or-waste stack are continuously being blown out. What would cause this to happen?
A. An oversized vent stack.
B. An overiszed stack vent.
C. An undersized vent stack.
D. An undersized stack vent.
C. An undersized vent stack.
Which device is installed within a hot water tank to prevent corrosion?
A. Anode.
B. Dip tube.
C. Cathode.
D. Vacuum relief.
A. Anode.
What could be the problem if both elements are working in a hot water tank but you are receiving insufficient hot water from the tank?
A. Oversized tank.
B. Oversized piping.
C. Broken dip tube[]]
D. Leaking T&P valve.
C. Broken dip tube.
Which of the following test could be used to determine if a recirculating pump is experiencing cavitation?
A. Voltage.
B. Heat of the pump motor.
C. Pressure difference between the inlet and outlet.
D. Temperature difference between the inlet and outlet.
C. Pressure difference between the inlet and outlet.
What would cause the temperature and pressure relief valve on a natural gas fired hot water heater tank to start dripping whenever the burner is operating?
A. A broken dip tube.
B. Faulty T&P valve[][]
C. A leaking vacuum relief.
D. Waterlogged expansion tank.
D. Waterlogged expansion tank.
Which piping material may be used to replace a damaged galvanized water line in a historic building?
A. PVDF.
B. Galvanized pipe.
C. Polypropylene tubing.
D. ASTM A 53 iron pipe[]
B. Galvanized pipe.
What would be the result of a leaky foot valve on a jet pump installation?
A. Loss of prime for pump.
B. Low production for pump.
C. Low pressure in discharge line.
D. Intermittent relief valve discharging.
A. Loss of prime for pump.
What is the danger of water at or above 212°F in a hot water heater? (assume that the T&P has malfunctioned and allowed the water to get above 212°F)
A. The steel tank will rupture.
B. The water in the tank will vapourize.
C. There might be steam coming from the faucets.
D. Coper tubing is not rated for temperatures above 200D/F.
C. There might be steam coming from the faucets.
You are asked to go and service a hot water tank. The issue is that the tank seems to “rumble” when you fire it up. What could the issue be?
A. Water pressure is above 80 psi.
B. Excessive condensation in the B-vent.
C. Faulty temperature and relief valve[][][][]
D. Hardness scale buildup on the bottom of the tank.
D. Hardness scale buildup on the bottom of the tank.
How do you change the top element in a hot water tank?
A. Shut off power, change element, turn on power.
B. Shut off power, shut off water, change element, turn on water, turn on power.
C. Shut off water, drain tank, shut off power, change element, close drain, turn on power, turn on water.
D. Shut off power, shut off water, drain tank, change element, close drain, turn on water, turn on power.
D. Shut off power, shut off water, drain tank, change element, close drain, turn on water, turn on power.
What will happen if the water level drops in an electric hot water tank?
A. The tank will implode.
B. The T&P will discharge.
C. It will burn out the top element.
D. It will burn out the bottome element.
C. It will burn out the top element.
A urinal tank continues to flush. What component could be faulty?
A. The siphon.
B. The hush tube.
C. The control stop.
D. The float control valve.
A. The siphon.
There is a leak in the waterpipe between the city main and the property line. Which valve needs to be closed in order to fix the leak?
A. Curb stop.
B. City gate valve.
C. Corporation stop.
D. main stop and drain.
C. Corporation stop.
How is the flush affected if the bypass orifice is partially blocked on a flush valve?
A. Longer flush.
B. Shorter flush.
C. Will not flush[]
D. Continuous flush.
A. Longer flush.
How would the flush be affected if the diaphram in a flush valve was ruptured?
A. Longer flush.
B. Shorter flush.
C. Will not flush.
D. Continuous flush.
D. Continuous flush.
A residential shower has a pressure balancing valve installed. You notice that the water temperature is a little too hot for the users. How would you correct the issue?
A. Adjust the limit stop.
B. Replace the pressure balancing valve.
C. Increase the size of the hot water inlet piping.
D. Decrease the size of the cold water inlet piping.
A. Adjust the limit stop.
A hot water heating system has three zones. Two of the zones are working fine, but when the third zone valve opens, the circulator does not start and the burners do not fire. What is the most likely cause?
A. The primary relay coil needs replacement.
B. Outdoor boiler reset needs to be adjusted.
C. Corroded termainals on the boiler flow switch.
D. Faulty end switch on the zone valve[][][][][][][][][]]
D. Faulty end switch on the zone valve
Air is spurting around the rod of a reciprocating pump. The problem is likely that:
A. The piston is loose.
B. The pump is air locked.
C. The rod packing is leaking.
D. The pump is producing too much pressure.
C. The rod packing is leaking.
To repalce a faulty spring (coupler) on a dry-rotor circulator:
A. Disconnect power, remove set screw and pull motor.
B. Disconnect power, loosen set screw, remove bolts and pull motor.
C. Drain system, disconnect power, remove set screws and pull motor.
D. Drain system, disconnect power, loosen set screws, remove bolts and pull motor.
B. Disconnect power, loosen set screw, remove bolts and pull motor.