Flows/Procedures 747-400 Flashcards
Trigger, and Before Start procedure flow.
Trigger: Cleared to pressurize hydraulics.
- APU Gen 1 and 2 Verify ON
- Hyd. demand pump 4 - AUX, verify 3000Psi
Hyd. demand pumps 1, 2, 3 - Auto - Fuel Pumps - On (Center only if more than 7.7)
- Beacon - Both
- Recall - Verify ENG 1, 2, 3, 4 Shutdown, (If fuel TANK/ENG on - OVRD 2, 3 OFF, and X-FEED 1, 4 OFF)
- Cancel
(CAPT SETS STAB TRIM and calls for “BEFORE START CHECKLIST”
Trigger, and Engine start procedure flow.
Trigger: Cleared for pushback:
- Transponder - ICA: AUTO (TA/RA OFF), ICB: ALT ON (Only at airports with ground surveillance)
Trigger: Ground clears you to start the engines
- ENG PAGE on lower EICAS.
- PACKS - 2 PACKS OFF.
CAPTAIN: Starts engine.
*Expect HYD PRESS DEM 4 after engine 4 Started.
Trigger, and Before taxi procedure flow.
Trigger: Pushback / Engine start complete.
- APU - OFF
- Hyd. deman pump 4- AUTO
- NAI - As needed.
- AFT Cargo heat - as needed
- Packs - NORM.
6, STAT page on Lower EICAS
Wait for hand signal / wave off
- FLAPS 20
CAPT does flight control check
- RECALL - CANCEL
- Blank lower EICAS
Captain calls for “Before TAXI Checklist”
Trigger, and Before takeoff procedure flow.
Trigger: Clear of ramp, approaching runway.
- Choose WXR or TERR display - ON
- Cabin announcement.
PF calls for “Before takeoff checklist”.
Trigger, and Descent procedure flow.
Trigger: FMS set up for approach - STAR / APP / LEGS
- BARO - Preselected QNH
- MINS - Set minimums
- ECS Page - Verify landing altitude
- Recall - Cancel
- CDU Init ref - set VREF
- CDU NAV/RAD - Set nav radios
- CDU DEP/ARR - Verify STAR / APP
- CDU VNAV - OFFPATH, DESCENT FORECAST.
- AUTOBRAKES - As needed
Approach briefing.
PF calls for “DESCENT CHECKLIST”
Trigger, and After landing procedure flow.
Trigger: Speedbrake down
- AUTOBRAKES - OFF
- Transponder - ICA: AUTO (TA/RA off), ICB: ALT ON (only at airports with ground surveillance).
- FLAPS - UP
- WXR - OFF
- STAT page on lower EICAS
- Lights - STROBE, LANDING LIGHTS off
Approaching the stand:
7. APU - start
Trigger, and Shutdown procedure flow.
Trigger: At stand, Parking brake set, APU running.
- Electrical power - establish (APU GEN 1, or EXT 1 if available).
——–If towing required——-
- Hyd Demand pump 4 - AUX, Hyd demand pumps 2, and 3 - OFF.
After towing is complete, Hyd demand pumps 1 - OFF
——–If towing not required——-
- Hyd demand pump 4 - AUX, and 1, 2, 3 OFF.
* CAPTAIN puts Fuel control switches to cutoff. - ANTI ice - OFF
- Fuel Pumps - OFF
- Beacon - OFF
- FD (BOTH) - OFF
- Transponder - SBY
- Seatbelts - OFF
Chocks i / Parking brake released
9) Hyd demand pump 4 - OFF.
Captain calls for “SHUTDOWN CHECKLIST”
Secure procedure and flow.
No trigger.
1) IRS - OFF
2) Emergency lights - OFF
3) AFT Cargo heat - OFF
4) Packs - OFF
“SECURE CHECKLIST”