Fire Protection Q’s Flashcards
A hand held fire extinguishers weight is stamped on the
Head
An indication pin protruding from a portable fire extinguisher what does it indicate
Bottle is empty
A cabin hand held fire extinguisher by regulation must be operated by
A single handed operation
C02 fire extinguishers are used on
All fires in fuselage
Extinguishants suitable for use in cabins are
Water and BCF
Hand held fire extinguishers are weighed
In accordance with the approved maintenance schedule
How can a fire extinguisher be incentivised as being used
Weighed
How many fire extinguishers are required on an aircraft having 401-500 pax
6
How many fire extinguishers are required on an aircraft having 501 pax
7
How often do handheld extinguishers have to be weighed
Annually
Portable fire extinguishers are operated by
Breaking the tell tale / tamper proof seal then operated by the handle
The weight of an extinguisher is stamped on
The head fitting
What are the minimum number of fire bottles on a cabin with 201-300 pax
4 fire extinguishers
What fire extinguisher is used in the cockpit
C02
A mixed fire extinguishing system is where
More than one extinguishant is used
The resistive type fire wire is fitted in rubber grommets to
Prevent damage by vibration
A capacitance fire wire
Will work but not test if broken circuit
The single cell photo electric smoke detector
Relies on the production of a DC supply from a photoelectric cell
A cargo compartment which will contain a fire itself and ventilate
Must be modified to a class C or E compartment
A cargo compartment which will contain a fire itself and ventilate is a
Class D
The electrical supply for a two shot fire extinguishing system is
DC from the essential bus
A cockpit check on the engine fire wire system is a
Function check
A fixed system fire bottle is weighed
Without blanks and with detonators
If a fire bottle over pressurised
All extinguishant is lost
A fire detection loop must be capable of
Using master warning visual and aural signals
A thermocouple fire detector
Produces a DC supply when fire is detected
A fire detection system can pass through one zone to another providing
The system is protected
A fire detection system should be
Positioned in a location determined by the manufacturer during the design
In overheat conditions the resistance of the resistive type fire wire
Decreases
Fire wires
May have one or both ends connected to the control box depending on type
A fire detection zone wiring can pass through another fire zone when
The system and the extinguishing are the same