Fire Protection, page 09-10-1 Flashcards
What are the 2 subsystems of the fire protection system
Fire/overheat detection ad fire extinguishing
What 4 areas does the fire/overheat detection cover
Engines, Jet pipe/pylon, APU and main landing gear
What zone does the fire extinguishing system cover, A or B
Zone A, engines and APU
What does zone B area consist of…
jet pipe and pylon
Does zone B have fire extinguishing
No, just overheat and fire detection
How many fire bottles exists
- Two for the engines and one for the APU
Can the fire detection control units discriminate between an true fire/overheat and a short in the heat sensing element
Yes, EICAS will display a fire fail or jet pipe overheat fail
What are the 6 things that occur when the ENG FIRE PUSH switch/light is pressed
- squibs are armed 2. generator shuts down 3. fuel shutoff valves close 4. hydraulic SOV closes 5. bleed air SOV closes 6. ignitor is disabled
If a fire or overheat conditions is detected in the APU area what happens
APU automatically shuts down
Will the APU fire bottle automatically discharge if a fire is detected
No
Can the APU fire detection unit discriminate between a fire and a failure
Yes, EICAS will display APU FIRE FAIL
What six things occur when the APU FIRE PUSH switch light is pressed
- squibs are armed 2. APU shuts down 3. fuel SOV closes 4. Neg-G SOV closes 5. LCV closes 6. Gen shuts down