Aux Power Unit, page 05-10-1 Flashcards
What is the minimum wait time after shutdown to check the oil level in the APU
30 Minutes minimum
After shut down of the APU prior to opening the Gen/adapter oil filler cap what should be accomplished?
Push and hold the pressure-relief valve cap for 5 sec
Where does fuel normally come from for the APU
Right wing tank
If the APU fuel pump in the Right wing is inop is there a backup system
Yes, from the Left engine fuel manifold
What is the NOTE associated with using the alternate fuel system for the APU
APU is time limited from startup to shut down. Check the MEL. Basically used to start an engine and then shutdown.
Why is there a time limit alt fuel system
Due to prevention of fuel to enter the fuel-oil heat exchanger
Were is the APU battery located
In the aft equipment bay under the APU
How much time should be waited before applying bleed air from the APU
2 Min after reaching 100%
What are the 10 things that will automatically shutdown the APU
ECU failure, Fire, Overspeed, Over Temp, Low oil Press, High oil temp, Gen Adapt low oil press, Gen Adapt high oil temp, Loss of EGT sensor, underspeed.
If an emergency shutdown of the APU is needed how can this be done
by using the STOP Button on the APU Fault Panel located on the Left Rear Fuselage
What must be accomplished prior to starting the APU after an emergency shutdown using the APU fault panel
The APU switch/lights on the overhead panel must be pressed out