Emergency Equipment, page 08-10-1 Flashcards
The 115 cu. ft. baseline oxygen system is located were
Wardrobe area
How many psi is the total O2 system
1850 psi
where is the 40 cu ft bottle stored
under the cockpit floor on the right side
The drop down masks are designed for use below what altitude
25,000
If an O2 bottle pressure becomes excessive what happens
It is vented outside
The baseline discharge indicator is located were
On the left hand fuselage forward of the pax door
The 40 cu ft discharge disc is located were
Right hand fuselage forward side
How many psi is required to fragment a discharge disc
2800 psi
The amber OXY LO PRESS message will display when the O2 press drops below what
825 psi
Where is the O2 service panel
Right nose section behind the avionics door
On the Passenger O2 panel on the copilot’s side console what do “Close”, “Normal” and “Override” mean
Closed- cuts off all O2, Normal-Masks drop at 14K and supply O2, Override- Masks deploy and O2 is supplied
Emergency lights will last how long
About 15 min