Fire protection Flashcards
What Happens when you pull the Fire EXTG Handle?
Closes associated-
-Hyd SOV
-Fuel SOV
-Engine Bleed Air Valve
-And as Engine decelerates
Generator Line Contactor Opens
Smoke Detected IN FLIGHT.
What Happens if I push the FWD CARGO SMOKE button?
A SINGLE push will-
Discharge HIGH rate bottle and 60 sec later, the LOW rate bottle will discharge automatically.
Smoke Detected NOT In Flight
What Happens if I push the FWD CARGO SMOKE button?
A single button push will-
ARM the High Rate bottle
Second Push will-
Discharge HIGH rate bottle then 60 sec later discharge the low rate bottle
When would APU light illuminate ?
When APU EMER STOP Button has been pushed in and APU Fire is detected.
Or
60 seconds after an APU fire is detected and no Pilot action has occurred.