APU Flashcards

1
Q

APU is the Only Source of Power:

Will AC Power be lost immediately when the APU is Turned off?

What about APU Pneunatics?

A

No. APU provides power for 1 minute if no other AC power source is available.

    APU Pneumatics will be removed immediately
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens if you turn the APU switch back to ON during its 1-minute Cool down period ?

A

APU will provide electrical power to electrical system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Can you do a Pre-Flight Walk around with the APU Running? Why or why not?

A

Yes,
because you are considered in the footprint of the aircraft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens when the EMER STOP
(Guarded) Button is pushed IN?

A

Closes the APU Fuel SOV.
Shutting APU down with out 1 minute cooldown

   Also white stripe illuminates on bottom half of switch
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

With NO fire indication, would anything happen if the guarded APU button ( on the fire extinguisher panel ) is pressed?

A

Yes, the APU SOV will close and the APU Fire extinguisher would discharge.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

GPU is powering the aircraft AC Power:

•Will APU provide AC Power to the Aircraft?

•How are APU Pneumatics affected?

A

•Power will be cut off immediately

•They will also be cut off immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Will a APU FADEC Fault command an automatic shutdown of the APU?

A

Yes, APU FADEC Faults will command auto shutdown of APU within 10 Seconds after the fault is detected.