Fire Main & Sprinkler System Flashcards

1
Q

What type of fire does the Fire Main System fight?

A

Class A fires

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What sea chests are in each engine room? State when each sea chest is used.

A

Low & High sea chest
Low seachest in open waters, High seachest at port or shallow waters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What fire pumps are in the FWD & AFT engine room?

A

AFT: 1,2,3
FWD: 4,5,6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the capacity and delivered pressure of a fire pump?

A

Capacity: 200m^3/h
Delivered pressure: 9.0 bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In the engine rooms, which fire pumps are paired and usually used for fire fighting? What are the remaining fire pumps mainly used for?

A

FWD: 2,3
AFT: 4,5
Remaining fire pumps 1 & 6 are used for activating the bilge eductors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

State the 9 locations that the sprinkler system covers.

A
  1. Armoury 1 & 2
  2. Gunbay
  3. Tank deck Zones 1 - 5
  4. Hanger/elevator room
  5. Ammo room
  6. Fwd/Aft Flight deck
  7. Aviation fuel pump room
  8. Aviation fuel dispenser rooms 1 & 2
  9. Mission planning room
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Describe the flow of seawater from the fire pump to the hangar.

A

Fire p/p → Engine Room “Ring” → Connecting firemain pipes → Tank Deck “Ring” → Connecting firemain pipes → Hangar “Ring”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

State the 3 tiers of control points for activation of fire pumps and their locations.

A

Tier 1: Group Starter Panel - E/R
Tier 2: RCV Panel - FWD E/R
Tier 3: SCMMS pg 44 - MCR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What modes must the GSP and RCV panel be set at to transfer control of the fire pumps to the GSP, RCV panel, and SCMMS?

A

To transfer control to GSP: GSP MANUAL
To transfer control to RCV Panel: GSP RCV PANEL + RCV Panel LOCAL
To transfer control to SCMMS: GSP SCMMS + RCV Panel SCMMS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

State the 3 tiers of RCVs for sprinkler system and their locations.

A

Tier 1: RCV Cabinet - FWD E/R
Tier 2: RCV Panel - FWD E/R
Tier 3: SCMMS pg 44/45 - MCR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What mode must the RCV panel be set at to transfer control of the RCVs in the sprinkler system to the RCV Cabinet, RCV panel, and SCMMS?

A

To transfer control to RCV Cabinet: No switch required.
To transfer control to RCV Panel: RCV Panel LOCAL
To transfer control to SCMMS: RCV Panel SCMMS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Describe the 4-step sprinkler system activation sequence.

A
  1. Ensure presence of power supply to selected fire pump
  2. Ensure all necessary valves are at their desired operational position
  3. Select mode of operation & start the selected fire pump, THROTTLE (partially open) the FP O/B v/v to achieve desired Fire Main pressure. Check pressure gauge to 9-10 bar
  4. Open valves to selected coverage area
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What’s the desired position of the operational valves before activating the sprinkler system?

A

OPEN the following valves:
High/Low S/C
FP inlet
FP outlet (RCV)
Supply to E/R ring for FP 2/3/4/5
Main Engine and Generator Emergency cooling v/vs

CLOSE the Supply to E/R ring for FP 1/6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Which 3 locations require 2 valves for emergency cooling in case the sprinkler system fails?

A
  • Armoury 1 & 2
  • Gun Bay
  • Ammo Room
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

State the locations of the 3 valve connection points from Engine Ring to Tank Deck Ring.

A

AHU 8 & 9, Machinery Storage Room and Machinery Room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly