Fire Detection and Protection Flashcards
Describe the APU fire protection
1 bottle
3 pairs of detectors 2 loops (both need to sense or no discharge)
Auto or Manual
15 sec delay air or grd
if Eng off if either loop detects bottle goes
Is there Fire detection and protection for Wheel Well
Detection for Fire and overheat
no Protection
dual detector channels
What separates the AFT and Bulk Cargo compartments
Curtin
How many fire bottles for the cargo
6
Is the Cargo Fire protection on Auto all the time
No Manual on the ground
is there fire protection in the OFCR/OFAR
no
just portable hand held extingiusher
What is the indication of a Lav fire
EICAS - LAV SMOKE DET
Describe the Eng fire system
4 pairs of detectors (2 Channels)
if only one of the pair sense fire it ignors
Fault yellow on the EICAS caution
What happens when a Eng fire switch is pulled
Armed Exting fuel valve closed Anti ice off Gen off HYD off Thrust rev off
Describe the Cargo compartment
Ground and Air
divided into FWD and AFT (AFT and Bulk)
3 Zones
In flight - 2 bottles immediatly
- 4 bottles at a low rate 15 min
land - Manual - 3 discharge simultanously
- 3rd bottle at a reduced rate
Why does the Land ALT selector Auto to 8,000
Minimizes agent leak out of compartments