Pushing the ENG FIRE pb does:
A
(work panel downwards)
1. Removes power to the FADEC
2. Silences the CRC
3. Arms the Squibs (Fire)
4. Closes the Hydraulic Fire Shutoff Valve (Hyd)
5. Closes the LP Engine Fuel Valve (Fuel)
6. Deactivates the IDG (Elec)
7. Closes Pack Flow Control Valve (Air)
8. Closes the Engine Bleed Valve (Air)
2
Q
Cargo Fire Protection design
A
Pair of Optical Detectors attached to separate detection loops (loop logic).