APU Flashcards

1
Q

Actions and Limits: “LOW OIL LEVEL” ECAM

A

If ECAM displayed on the APU SD page prior to start: Advise Maintenence. Limited to 15 hrs use after message is displayed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Starter Limits

A

3 starts, 60 min cooldown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Start limit (normal aircraft supply vs. APU battery only) altitudes

A

Normal: 41450 ft
APU BAT: 25000 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Operating Envelope Altitude Limit: APU Electrical Use

A

41450 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Operating Envelope Altitude Limit: APU Electrical Use + APU bleed for 1 pack

A

22500 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Operating Envelope Altitude Limit: Engine Start using APU bleed

A

20000 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Operating Envelope Altitude Limit: APU Electrical Use + APU bleed for 2 packs

A

17500 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Exterior Locations to shutdown APU

A
  1. Refueling Panel
  2. External Power Panel
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

APU Bleed valves automatically close climbing through ____ and reopen passing _____

A

ECB (Electronic Control Box) closes APU Bleed Valves climbing thru FL250 and reopen descending thru FL230

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens in case of APU Fire on ground

A
  1. APU FIRE Warnings in Cockpit
  2. Horn in nose gear bay sounds
  3. APU “AVAIL” light extinguishes
  4. “FAULT” light in Master sw illuminates
  5. APU Shutsdown
  6. APU Fire extinguisher discharges
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

APU Master sw FAULT means?

A

Automatic shutdown of APU has occurred.
On ground: overspeed, ECB (Electric Control Box) critical failure, underspeed, start abort, low oil pressure, high oil temp, load compressor overtemp, generator high oil temp, DC power interruption (disconnect when aircraft on BAT only), overtemp
In Flight: Overspeed, certain critical ECB internal Failures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

APU Master sw FAULT means?

A

An automatic shutdown of APU has occurred.
On ground: Overspeed, ECB (Electric Control Box) critical failure, under speed, start abort, low oil pressure, high oil temp, load compressor overtemp, generator high oil temp, DC power interruption (disconnect when aircraft on BAT only), overtemp
In Flight: Overspeed, certain critical ECB internal Failures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

APU MASTER SW pb

A

Controls the electric supply for APU operation, its protective features, and start/shutdown sequences
FAULT: Automatic shutdown occurred
ON/R: Electric power to APU system, ECB power up test, APU air intake flap opens, APU fuel isolation valve and APU LP valve open, fuel made available
OFF: Manual Shutdown sequence; APU first runs for 15 s (no break in power transfer), if APU BLEED selected, APU performs cooling period for 85 sec at 82% N, at N 7% air inlet closes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

APU START pb

A

ON: blue light, when flap is completely open APU is energized, when N = 7% ignition on, N = 50% starter de-energized/ignition off, N = 95% “ON” light extinguishes.
AVAIL: green light, when N reached 95%, bleed air and electrical power available.
note: “AVAIL” remains on during, cooldown can take up to 2 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

APU Fuel Supply

A
  1. Engine 1 Collector Cells: on ground after 2 minutes (except during trim tank refueling), or inflight below FL255, or above FL255 when trim tank empty.
  2. Trim Pipe: first 2 min on ground, or during trim tank refueling, or during aft transfer
  3. Trim Tank: Above FL255, or during forward transfer

Fuel must be maintained in trim tank transfer line (trim pipe) for APU to function.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

APU battery voltage below ____V risks an aborted APU start

A

23.5 V