Faults - Xtrap Flashcards
How long is battery power?
60 minutes
Ways to conserve battery power in event of loss of overhead? (6)
- reverser to neutral
- MC to off
- headlights off
- (daylight) saloon lighting to emergency
- (daylight) cab lighting off
- Step light off by closing doors
Low pressure in BP fault light comes on when BP has reduced to what KPA (during rescue)
Below 430k
What does BP need to reduce to that results in train fail when in rescue?
300k
Low pressure in MRP fault light indicates MR has fallen to what KPA?
Below 650
MR pressure drops to what KPA to result in train fail?
580
3 locations for CB’s?
Drivers cab
Traier saloon (left of door 2)
E box on each car
6 CB’s left of door 2 in trailer saloon?
Tachy Unit
BCU
Panto 2
Panto 1
Auxiliary 2
Auxiliary 1
Can drivers reset CBs on e box?
No
How many times can a fault be reset?
3x
Faults that can be rectified by train stable?
If possible, when in running where should a train stable be performed?
Station platform, under the protection of home signals, or where level crossing protection devices will not remain active
How long does a train stable take?
2 minutes
How many seconds do we wait before removing controller key after 1 or panto down status light illuminates?
5 seconds
When stabled, how long will marker lights and emergency saloon lights stay illuminated?
15 minutes
4 reasons why step light may not be illuminated
Defective
Storage batteries flat
Batteries have been iso
Battery box fuse blown
On start up if panto has no risen what do we check first?
Voltmeter
After checking voltmeter and there is NO VOLTAGE, where do we go?
Check position of battery box iso switch.
If isolated report TMM
If not isolated declare disabled
Checking voltmeter and there is power but under 90v what is the train?
Disabled
How many seconds do we wait for high voltage presence light to illuminate after raising pantos?
30 seconds
If pantos won’t raise and voltmeter os above 90v, what do we check?
Local and trailing panto buttons not latched it.
Attempt to raise panto from other cab
If pantos fail to raise from another cab and buttons not latched in, what can we check?
Trailer car Right of door 4 - 3 way switch. Check is in automatic position
If panto 3 way switch is in ma ual lowering or isolated position can we still raise pantos?
No, report to TCA
What else can we check in trailer car if pantos won’t raise (and we’ve checked 3 way switch)
Panto 1 and 2 CB in cabinet left of door 2
How to isolate panto?
Stable
If lowered - place 3 way switch to manual lowering and isolate position
Activate cab to raise other panto
If panto fails to lower when isolating what do you do?
Manually lower and isolate with 3 way switch and crank handle
When coasting under a tramway square, what emergency trainswt mode should you switch to?
1
If you see “other cab operative” light, what steps must you take?
-Cab 2 cab
-Inspect each cab for a key/cleaners key
-if no key found ascertain which the active cab is
-if not able to be deactived then train stable
If unable to rectify other cab operative fault, which cab can be driven from?
Can only be driven from the active cab
Things to check if emergency brake not releasing
If unable to rectify cause for emergency brakes not releasing, how must train be run?
Safety loop bypass
When running on safety loop bypass, how will emergency brakes apply?
If bypass switch is let go it returns to normal position causing the emergency brakes to come on
What equipment is not available when safety loop is bypassed
Should the hand or foot pilot valve become to defective, what can you do?
Auto vigilance bypass
How often will auto vigilance bypass button flash?
30 seconds
During overhead loss how long will VICERS continue to run off internal battery prior to shutting down?
2 minutes
Are batteries confined to a 3 car?
Yes
How to rectify a defective battery charger fault?
Perform train stable
During SIV failure, how long can the battery charger fault light stay illuminate while the other SIV takes over charger circuits?
2 minutes
Effect on train with 1 siv failure?
1 HVAC operate on 3 car
1 air compressor operate on 3 car
Failure of both sivs effect on train?
All HVACs
Battery charger
Both compressors
Both traction cooling fans
SIV failure rectification
Check aux CB in trailer car
Stable
Where is door no.1 electric motor located in a motor car?
Driver cab
4 positions of the door motors switch
Release
Isolate
Normal
Lock close
What 3 things happen when door motor switch is put up in the release position?
FDCL
Door release push button will extinguish
Saloon door can be manually moved
What 3 things happen when motor switch is down In the lock close position?
Steady door close light
Door release push button extinguishes
Saloon door is locked and closed
What 4 things will indicate a DER has been operated?
FDCL
DER fault light
Flashing red ANSW button
DDU emits a tone
How to reset DER
Turn tri key anti clockwise against spring tension
How to isolate defective saloon door?
Motor iso switch to RELEASED
Close door manually
Motor iso switch to LOCK & CLOSE
door not in use stickers
Hiw do you isolate traction motors?
The TCU isolates them
4 indications a driver may get when traction motors have been isolated
Traction fault light
1 or more traction equipment fault light
No green LEDs on power indicator
Possible shuddering
Is the traction fault light train lined?
No, it pertains to this car
How can a driver rectify traction issues quickly?
Stable
How can a driver locate a traction equipment issue?
Activate each cab
Locate the traction fault light and 1 or more
Place isolate traction switch to isolate to remove train lined fault light
Book FMP
What does thus fault mean?
Tacho speed sensor has failed
Where is the tacho CB?
Left of door 2
What equipment is effected when a tacho cable has failed?
Door release
Uncouple button
Trip reset
No speedo
BP won’t charge after my application
Vicers reset
How do you rectify tacho cable issue
Stable
Tacho bypass
Is speed input and wheel slide related?
No
110v/24v DC inverter failure - what equipment should we look for?
Headlights (low)
Drivers seat adjustment
Marker lights
Speedo
Wiper washer
Voltmeter
MAD
Cab spotlight
CCTV
External brake indicator lights
If using portable radio, do I need to be stationary?
Yes
How to clear a DTRS fault?
Press X on keypad
How to rectify DTRS faults
Deactivate cab
Trip and reset DTRS Cb in cab
Activate cab
If PA is Inoperative what do we use?
DTRS PA
If both PA microphones are inop what do we do?
Stable
Wait an additional 4 minutes and retest PA
Major, major 2nd level and minor fault lights indicate what?
CB has tripped
Safety loop CB has tripped
Check e box
-Need to reset VICERS acknowledgement button
Speed = 0
MC in coastal
EMY brake applied
SIV 1 and 2 have failed
Place MC to full service
Place emergency trainset mode to 1
Release brakes and immediately reapply
What res must be drained prior to manually release SPB
Auxiliary res
Can both compressors operate simultaneously if MRP drops below 650?
Yes
If 1 compressor fails on a 3 car will the second compressors take over?
Yes
What to do if MRP is between 580 and 750
Book and continue to monitor
What to do if MR pressure below 580
Safety loop will open
Confirm high voltage light on
If not on-
MR leak likely, go and check
What to do if compressors not running
Stable
MR leak under centre motors
Try to plug, if unable to-
Isolate MR cocks
Manually release SPB
Book and drive as per bogie isolated instructions
MR leak under any other car (not centre motors)
Attempt to plug, if unable to-
Train disabled
If MR leak and disabled and leak is on leading motor of lead trailer, which direction to be rescued?
From advance
3 types of trip failures
Lower
Raise
Reset
If trip cock fails to lower and after attempting to raise and lower again
TEC call
RTA
check trip cock active cock in auxiliary pneumatic panel
If cock open then place trip cock device switch to raised and run on secondary circuit pressing auto vig button
How many seconds will auto vig button time out?
40
Whistle defect sounding continuously
Isolate low
Isolate high
Isolate whistle cock
Locked Axel
What are the 3 rescue features of an xtrap?
EMS
Brake pipe
Brake pipe sensor
5 positions of the EMS
1 holding brake
2 normal
3 rescued
4 rescuing
5 rescuing in propulsion
What EMS modes are used when non electrically rescuing?
3 4 5
Brake pipe sensor opens and closes safety loop at what pressures?
Opens 300
Closes 430
In a loss of 110 what switch must be turned to allow trickle charge from assisting unit?
Safety loop rescue switch
What BP kpa is traction cut when in positions 4 or 5 on EMS?
480
When coupled non electrically what brake is available?
Emergency
How to charge brake pipe?
Both trains MC in full service positon
Safety loop rescue dwitch must be placed to rescue in what cabs
Disabled train - all cabs
Assisting train - lead cab
Max combined train length when xtrap pulling xtrap that has battery power Insufficient to release s loop
12 cars
Max combined train length when xtrap pushing xtrap that has battery power Insufficient to release s loop
9 cars
When xtrap is pushing a disabled train, what must the EMS be turned to in the disabled train?
Number 1 online holding brake inhibit
When xtrap is pushing a disabled train, what must the EMS be turned to in the assisting train?
Number 4 rescuing
When xtrap is pulling a disabled train, what must the EMS be turned to in the disabled train?
3 rescued
When xtrap is pushing a disabled train, what must the EMS be turned to in the assisting train?
4 rescuing
What is operated by 400V (BATH)
Battery charger
Air compressors
Traction cooling fans
HVAC
When stabling what do we tell passengers?
2 minutes where saloon lights will be reduced and doors will lock
How to rectify service brake fault
DURING TRAIN PREP
MC to full service
EMS to no.1
Release brake and immediately apply
Service brake fault light, how to tell if axle is locked on a traction motor?
Traction fault light as well
If compressors are failing to operate what can we do?
Stable
If we have 1 or more brake applied while in motion, how to we rectify?
Likely sticking brakes
Isolate bogie
If we need to drive from another cab due to another cab active fault light, what do we need?
Competent employee
Reasons to isolate vicers
Fault indicator illuminates
Safety loop bypassed
Auto vigilance bypassed
Abnormal operation
Where is the panto motor switch located?
Right of door 2
When a train is stables how long will marker kughts and emergency saloon be illuminated?
15 minutes
Where are door electric motor switches located?
Left of every saloon door
Can safety loop bypass be operated if MR pressure below 580?
No, must be sandwiched due to no emy brakes
When does the ALL BRAKE APPLIED fault light turn on?
When EMS is in position no.1