When rescuing a train and you’re pulling it out of section and it has no pantos up, what cock do you need to turn?
Techav (to remove trip)
???? Saloon lights - running emergency
Yes
Trips switches guages cocks, what’s next?
DC supply light
Hiw can you tell you have no DC supply
No bell
LP flag raised
What is the control res pressure
490kpa
Effect on train if you have control res rupture
Line breakers fail to close
If a control res has ruptured, what fault lights will you get?
Line switch
If you have a control res rupture how do you isolate motors?
Motors all out
What can you press in the cab if you have traction issues
Traction overload
Do we touch the main switch?
No
What 3 things are supplied by the 1500v DC
MA, compressors, traction motors
How many times does substation restart during overhead loss?
2x
During overhead loss what happens to doors?
Release
Overhead loss - what will all trains in section be asked to do?
Lower pantos
Overhead loss, with comms, at what time intervals will trains depart once overhead has been restored
One minute intervals
During overhead loss and trains begin to clear the section again, what notch of power should they use?
Series
AC power items (3)
Non-emergency saloon lights (normal lighting)
Van area cab light
Operation of headlights
Overhead loss and no comms, at which time of the clock will UP trains and DOWN trains move?
⬆️ 30 seconds
↕️ 60 seconds
Overhead loss, how long will battery backup last?
2 hours
Wheb overhead power is lost, what fault light will flash on drivers fault panel?
Battery charger (to indicate a reset of the emergency lighting is required)
What does the LSM do?
Protects the sub station from the train
LSM speed threshold for time delay?
8km
Overhead loss, LSM activates when the output of MA’S drops below what voltage?
95vDC for 2 continuous seconds
During overhead loss what two things are still available?
Emergency lighting
PA systrm
LSM operation - train moving over 8km/h, BVICS open overhead lost, timers WITHIN 4 minutes - what does LSM do to train?
Lowers all trailing pantos
Shuts down local MA
Trips EP CB
Overhead loss - to locate defective train, Train Control will request drivers to do what?
Raise each panto individually
Start each MA locally
Overhead loss - how many minutes until vicers times out?
5 minutes
Will traction overload button work if MAs have oversped
No
How to isolate rheo brakes?
Toggle switch
What does a steady air con light indicate
1 AC in 1 car down
What does a flashing aircon light indicate
More than 1 AC in 1 car down
Where is the fault if the wheel slip fault light illuminates while stationary?
Wheel slip unit
Wheel slip axle km difference
15km
What is part of the control CB
MRBOPC
Master controller
Reserver
Rheo brake
Traction overload
Panto raise and lower
Control govener
What happens to train if control CB trips?
Fail to power
If you’re leading panto fails to raise, how will you get your pantos up?
Raise individually
If your pantos won’t lower what happens to train?
Out of service
If control cb trips in trailing cab, what indication will you get in lead?
FDCL
???? Scenario based question about locating control CB trip cause
Reverser is the cause
???? Scenario based question about locating control CB trip cause
Rheo demand wire is the cause
How to isolate rheo train lined?
Flip EP CB
???? What is the lowest % of traction motors (isolated bogies?) can you continue driving with
50%
???? (Forget how the question was worded)
Is 110v train lined?
Yes
How many MA’S need to be running for full saloon lighting?
All
1 MA running effect on train
Half saloon lighting each car
Half AC each car
Local rheo brake will be inoperative