Ampere turn formula
Current (amp) x # of turns = ampere turns
Variables impact required current using a solenoid
- Part geometry
- Part size
- Part length
- Part Positioning
Part Geometry impact on solenoid inspection
Length to Diameter Ratio:
between 2 and 15, any less require a “pole piece” to increase the ratio.
Part Size impact on solenoid inspection
Fill Factor:
cross sectional area exceed 10% of inside coil diameter opening.
Part Length impact on solenoid inspection
Limitations of Longitudinal Fields:
length or section of part must not exceed 26cm (18in) or 13cm (9in) on either side of coil, if it does exceed must be inspected in sections.
Part Positioning impact on solenoid inspection
Maximizing Field Strength in Part:
test part must be in contact with inside part of coil wall.