Engines Flashcards
What type of Engines?
N1 / N2 consist of
How much Thrust
CFM56
Fan/ 3 stage compressor driven by/ 4 stage turbine
9 stage compressor driven by / single stage turbine
32,000lbs
IAE V2500
Fan/ 4 stage lp compressor/ 5 stage turbine
10 stage hp compressor/ 2 stage turbine
33,000lbs
What controls the Engines?
How many Channels and if one fails will the other takeover automatically?
FADEC (full authority digital engine control)
Some manuals refer to it as the ECU (Electronic control unit)
2 channels and Yes
Where do FADEC get there info from?
Thrust Levers
FMS
Engine Master Switches
EIU- engine interface unit
receive info from LGCIU, FMS, and ADIRS
Where are primary engine indications displayed?
Secondary indications are found?
E/WD engine and warning display
Engine and Cruise pages
How many fuel nozzles?
What controls igniters
20
FADEC
When TRs deploy it directs_______air forward
FAN
What drives the accessory gear box?
What is on the accessory gear box?
N2 rotor
Engine Oil Pump
Engine Fuel pumps
Hydraulic Pump
FCU
FADEC alternator
IDG (engine driven integrated drive generator)
What does the FADEC do?
Auto Eng Start
Auto Eng Start Adjustment
N1 & N2 OVERSPEED protect
EGT exceedance during start on ground
(Does not protect against EGT exceedance in flight)
Min idle speed adj
Adj of max thrust values
Manual input thrust adjustments
Regulation of Rev Thrust sequence
Display of parameters on ECAM
Detection, isolation, and recording of Eng failures and presents it on E/WD
FADEC can be powered 2 ways
Electrical system
Eng driven alternator ( on this after start and through flight then switches back to electrical system after shutdown)
On the IAE engine only selecting engine anti ice on
Activates the ______
Igniters
When Eng mode is moved to eng start what does that do to pack flow control and why?
Closes them
For sufficient bleed air during start
Moving engine mod back to ign start once eng are started does what to igniters?
Activates continuous on both engines
When will you get a fault light on eng panel?
Aborted start
Disagreement between HP valve and it’s commanded position
TOGA thrust is limited
2 eng
1 eng
5 min
10 min
Min oil quantity for Eng start is
13 quarts