Engine 6 - Hydrants Flashcards
Smith Low Pressure:
Black barrel /silver bonnet
- 2 1/2 and 4 1/2 outlets
- number on barrel will indicate size of main
- white line under the number on the barrel indicates this hydrant is on a dead end main.
Dead end mains provide Less water
Dresser Low Pressure :
- black barrel /silver bonnet
- 2 1/2” and 4 1/2” outlets
- Dresser will provide 10% to 15% GREATER DISCHARGE than Smith
Eddy Hydrant:
- found in Jamaica Water Supply
- it opens and closes opposite regular hydrants
High pressure hydrants?
being removed and use should be avoided
35 foot Soft connection:
Yellow- 5 inch hose and 4 1/2” butts
FLAKE OUT prior to hooking up to hydrant
LARGEST WATER FLOW
10 FOOT SMALL:
-3 1/2” hose with 4 1/2” BUTTS
-closer and more accurate positioning
-semi-rigid-can be BENT and connected…
When charged, will STRAIGHTEN
10 FOOT hard :
-4 1/2” hose and 4 1/2” butts
-RIGID MATERIAL , very difficult to bend
DRAFTING
50 foot length of 3 1/2” hose
Permits MOST FLEXIBILITY
LEAST WATER FLOW
Hydra Shield :
threaded cap with 3 Indentations
wrench matches indentations
both 2 1/2” and 4 1/2” caps are provided with Hydra Shield
Custodian Hydrant Guard:
free spinning cap
SPECIAL WRENCH (CUSTODIAN WRENCH) equipped with magnet
Custodian wrench used to operate Custodian guard and Hydra Shield caps
under NO CIRCUMSTANCES should this wrench be struck with axe, sledge hammer
Installing HYDRANT PLUG—T BOLT:
- shut down hydrant and exam barrel for sharp objects and debris BEFORE inserting T-Bolt
- Maneuver T-Bolt through 4 1/2”opening into hydrant barrel
- maintain firm grip, prevent from dropping it
- place the threaded rod of the T-Bolt through the 2 1/2” opening and center it in the middle of the opening…non threaded end of T-bolt held inside in vertical position
- hold T Bolt firmly against the inside of the hydrant barrel with one hand and turn the handle onto the threaded end with other hand…Washer MUST BE ON OUTSIDE OF HYDRANT for plug to work correctly
- turn handle clockwise until tight
Make sure hydrant is _____before attempting to remove any caps?
SHUT DOWN
Yellow hydrants on parkways/expressways:
- shut down at CURB VALVE year round
- to use , MUST be turned on using CURB VALVE
- Assigned First Alarm Engines issued curb valve key
- for relocated units - LIST OF yellow hydrants and curb valve key located near HOUSEWATCH
- 18 TURNS to the right clockwise to OPEN FULLY (this valve should be fully opened before opening hydrant)
- do not force
Red Air cock hydrants :
- 30 inch or greater mains
- PAINTED RED/EXCELLENT WATER SOURCE
Red Satellite Water System Hydrant:
-TWIIN arrangement for SATELLITE UNITS
-Painted RED
Engine Companies should AVOID USE of these hydrants