Electric Flashcards

1
Q

The DC electrical system is supplied by:

A

3 NiCad batteries (24v DC)
2 Engine driven DC Starter-Generators (28.5v DC)
2 Transformer Rectifier Units (28v DC)
1 Auxiliary Power Unit (28v DC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Name the 7 DC busses.

A

Battery
Left and Right Essential
Left and Right Main
Left and Right Secondary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The AC electrical system is supplied by:

A

2 engine driven AC generators that provide 115 volt, three-phase, variable AC power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Automatic reconfiguring of the electrical system is controlled by the…

A

Electrical Power Control Unit (EPCU).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where are the batteries located?

A

Main and Aux - Lower Left section of nose compartment

Standby - Upper Left section of nose compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Volts and amp hours of batteries

A

Main and Aux - 24v, 40 amp hour

Standby - 24v 17 amp hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Batteries that assist engine start

A

Main and Aux

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How long will batteries supply emergency power?

A

Approximately 45 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which battery is connected to the “hot” battery bus

A

Standby battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

BATTERY MASTER switch

A

Closes 3 contactors directly connecting all three batteries to the Essential DC buses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How is the EPCU powered?

A

Indirectly from essential busses, Primarily from standby battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

MAIN/AUX/STBY BATT switch

A

Directly connects respective battery to its main bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What busses is the main battery connected to?

A

Right main DC bus (2 way flow), Right Essential Bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What busses is the aux battery connected to?

A

Left Main DC bus (2 way flow), Left Essential Bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What busses is the standby battery connected to?

A

Left Main DC bus (1 way flow for charging), Right Essential Bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Battery temperature range

A

Amber - 50C to 65C

Red - greater than 65C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What bus is external DC power is received by?

A

Left Main DC Bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

When will the EPCU automatically disconnect from the external power source?

A

External DC voltage exceeds 31 volts or drops below 22 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What are the DC starter-generators driven by?

A

Engine Accessory Gearbox

20
Q

How are the DC starter-generators cooled?

A

Air cooled

21
Q

How are the DC starter-generators monitored and controlled?

A

Respective Generator Control Unit (GCU)

22
Q

At what point does the GCU convert the DC starter-generator from starter mode to generator mode?

A

Nh of 50% during start

23
Q

What are the volts and amps of the DC starter-generators.

A

28.5 volts, 400 amps

24
Q

How are the TRUs cooled?

A

Air cooled

25
What do the TRUs do?
Convert 115 volt 300 amp variable frequency AC power into 28 volt DC power
26
How can you manually control the TRUs?
Respective circuit breaker located on the 115 volt variable AC circuit breaker panel
27
What is the APU start-generator rated at?
28 volts, 400 amps
28
When does automatic load shedding occur?
Loss of more than two DC power sources
29
What is EPCU emergency mode?
Loss of both DC generators and one TRU
30
What happens during EPCU emergency mode?
EPCU automatically disconnects the batteries from the main busses leaving them only able to supply power to essential busses (approximately 45 minutes)
31
Can the engines be restarted in the air in EPCU emergency mode?
Yes, EPCU will allow batteries to be momentarily reconnected to main busses
32
What happens when the EPCU detects a bus fault?
Automatically takes offline all the DC components associated with the faulty bus via isolation
33
How are the AC generators cooled?
Oil cooled
34
How are the AC generators driven?
Propeller Reduction Gearbox
35
How are the AC generators rated?
115 volt, three phase, variable frequency AC power
36
What components are powered by AC power?
- deicing/anti-icing heaters - standby hydraulic pump (#1 system) - TRUs - #1 and #2 aux fuel pumps - galley loads
37
Where are circuit breaker panels located?
- four flight compartment panels - DC contactor box in nose compartment - AC contactor box in left and right wheel well - two wardrobe circuit panels - galleys
38
#1 or #2 DC GEN HOT caution light
DC generator temperature is more than 166C
39
#1 or #2 AC GEN HOT caution light
AC generator temperature is more than 166C
40
#1 or #2 DC GEN caution light
DC generator not connected to its bus due to a source fault condition, the DC toggle switch is set to OFF, or the external DC power is energizing the main feeder busses
41
#1 or #2 AC GEN caution light
AC generator not connected to its bus due to a source fault condition, the AC toggle switch is set to OFF, or the external AC power is energizing the main feeder busses
42
STBY/MAIN/AUX BATTERY caution light
battery is not connected to its main feeder bus for charging
43
L or R TRU HOT caution light
TRU temperature is more than 71C
44
L or R TRU caution light
AC secondary feeder bus not energized by its related TRU because of a source fault condition or the AC generator toggle switches are set to OFF
45
DC BUS caution light
EPCU has reconfigured the main 28 VDC generation system because of a source or fault condition
46
L or R AC BUS caution light
AC generator not connected to its bus due to a right bus fault condition or the AC generator contractor is open while the generator is operating and the AC generator toggle switch is set to ON
47
STBY/AUX/MAIN BAT HOT warning light
battery temperature is greater than 71C