E8 L3 Environmentals Gauge Flashcards

1
Q

Stage of compression tap off for wing anti-ice

A

9th stage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Normal regulated system pressure by bleed valve

A

45-60 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Bleed air valve driven toward closed (temperature)

A

450°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Bleed air valve closed

A

490°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Pre-cooler bypassed

A

<360°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Precooler valve fully opened

A

> 425°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Pre-cooler discharge temp OVERHEAT illuminates

A

505°F (+/-10)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FIREWALL CLOSED light illuminates

A

70-80 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

FIREWALL CLOSED light extinguishes

A

73 (+/-1) psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

OVERPRESSURE light illuminates

A

83 (+/-2) psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

OVERPRESSURE light extinguishes

A

76 (+/-2) psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

ACM temperature output

A

35 (+3/-2) °F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

35 degree control valve fully open

A

33°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

35 degree valve closed

A

38°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Primary heat exchanger bypass valve

A

Maintain 60°F compressor inlet temp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Temp LEAK light illuminates in engine strut downstream on firewall SOV

A

310°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Temp LEAK light illuminates anywhere along wing

A

255°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

AIR COND UNIT OFF light illuminates

A

245°F turbine inlets

19
Q

AIR COND UNIT OVHT light illuminates

A

335°F compressor outlets

20
Q

CREW/MAIN CABIN OVHT light illuminates

21
Q

MAIN CABIN ALERT light illuminates

22
Q

Normal operating range in inches of water

A

4-20 inches

23
Q

Minimum inches of water to open trim air valve

24
Q

TURBO-FAN EXIT valves closed above

A

5000 ft AGL

25
VCM output temperature to PME
43°F
26
VCM PACK ON light time to illuminate
Up to 10 seconds
27
Time after (trip) reset before VCM back to ON
53 second
28
Number of VCM resets inflight
3
29
Equipment cooling VALVE OPEN light indicates
valve open more than 30 degrees
30
VALVE OPEN light extinguishes during climbout
2.8 psid
31
VALVE OPEN light illuminates during descent
1.8 psid
32
Draw Through OVBD VLV OPEN light
Overboard discharge valve open more than 3°
33
OVBD VLV OPEN light extinguishes after T/O
within 30 sec
34
COTS allowable temperature range
55 to 90°F
35
Pressurization in TAKEOFF position
Cabin altitude descends 250 ft below airport
36
Max differential pressure (both outflow valves)
8.6 psid
37
Pressure relief setting
9.42 psid positive / .36 psid negative
38
Emergency depressurization switch
1 psig of ambient within 60 seconds
39
Cabin altitude warning horn (LOSS OF PRESS)
10,000 (+/- 1000)
40
Cabin altitude override limits cabin altitude to
14,000 ft
41
Inner window cracked depressurize to
5.0 psid
42
Both windows cracked depressurize to
2.0 psid (inner and outer)
43
Stage of compressiong tap off for conditioned air