E8 L3 Environmentals Gauge Flashcards

1
Q

Stage of compression tap off for wing anti-ice

A

9th stage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Normal regulated system pressure by bleed valve

A

45-60 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Bleed air valve driven toward closed (temperature)

A

450°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Bleed air valve closed

A

490°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Pre-cooler bypassed

A

<360°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Precooler valve fully opened

A

> 425°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Pre-cooler discharge temp OVERHEAT illuminates

A

505°F (+/-10)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FIREWALL CLOSED light illuminates

A

70-80 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

FIREWALL CLOSED light extinguishes

A

73 (+/-1) psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

OVERPRESSURE light illuminates

A

83 (+/-2) psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

OVERPRESSURE light extinguishes

A

76 (+/-2) psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

ACM temperature output

A

35 (+3/-2) °F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

35 degree control valve fully open

A

33°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

35 degree valve closed

A

38°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Primary heat exchanger bypass valve

A

Maintain 60°F compressor inlet temp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Temp LEAK light illuminates in engine strut downstream on firewall SOV

A

310°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Temp LEAK light illuminates anywhere along wing

A

255°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

AIR COND UNIT OFF light illuminates

A

245°F turbine inlets

19
Q

AIR COND UNIT OVHT light illuminates

A

335°F compressor outlets

20
Q

CREW/MAIN CABIN OVHT light illuminates

A

190°F

21
Q

MAIN CABIN ALERT light illuminates

A

220°F

22
Q

Normal operating range in inches of water

A

4-20 inches

23
Q

Minimum inches of water to open trim air valve

A

4 inches

24
Q

TURBO-FAN EXIT valves closed above

A

5000 ft AGL

25
Q

VCM output temperature to PME

A

43°F

26
Q

VCM PACK ON light time to illuminate

A

Up to 10 seconds

27
Q

Time after (trip) reset before VCM back to ON

A

53 second

28
Q

Number of VCM resets inflight

A

3

29
Q

Equipment cooling VALVE OPEN light indicates

A

valve open more than 30 degrees

30
Q

VALVE OPEN light extinguishes during climbout

A

2.8 psid

31
Q

VALVE OPEN light illuminates during descent

A

1.8 psid

32
Q

Draw Through OVBD VLV OPEN light

A

Overboard discharge valve open more than 3°

33
Q

OVBD VLV OPEN light extinguishes after T/O

A

within 30 sec

34
Q

COTS allowable temperature range

A

55 to 90°F

35
Q

Pressurization in TAKEOFF position

A

Cabin altitude descends 250 ft below airport

36
Q

Max differential pressure (both outflow valves)

A

8.6 psid

37
Q

Pressure relief setting

A

9.42 psid positive / .36 psid negative

38
Q

Emergency depressurization switch

A

1 psig of ambient within 60 seconds

39
Q

Cabin altitude warning horn (LOSS OF PRESS)

A

10,000 (+/- 1000)

40
Q

Cabin altitude override limits cabin altitude to

A

14,000 ft

41
Q

Inner window cracked depressurize to

A

5.0 psid

42
Q

Both windows cracked depressurize to

A

2.0 psid (inner and outer)

43
Q

Stage of compressiong tap off for conditioned air

A

15th stage