DC Flashcards

0
Q

Who is the DCO?

A

CHENG, CDR Hagan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Who is the DCA?

A

Lcdr bibler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Who is the ADCA?

A

Ltjg AGUILAR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Who is the ships Fire Marshall?

A

LTjg carlos

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does DCTT stand for?

A

Damage Control Training Team

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Who is the DCTT Leader?

A

The XO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Who is the DCTT Coordinator?

A

Ships Fire Marshall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Who are the first responders to a casualty underway?

A

Flying Squad

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the job of the Rapid Response team?

A

Go straight to the scene and take appropriate actions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How many personnel are assigned to the Rapid Response team? What are they?

A

4; Fire Marshall, Electrician, 2 Investigators/Boundarymen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the Responsibility of the Rescue and Assistance team?

A

Back up for the At Sea Fire Party and assist other ships in distress

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

In what NSTM can you find information about surface ship fire fighting?

A

NSTM 555

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If you need to validate fittings on your CCOL, where would you look?

A

DC books

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What book contains step by step procedures for handling Casualties?

A

Repair Party Manual(RPM)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What book is used for combating fires in Main Spaces?

A

Main Space Fire Doctrine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If you need to keep a fitting open for an extended period of time what do you do?

A

Log it in the Material Conditions Violation section of the Closure Log

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How long can you keep it open?

A

No longer than 24 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What about fittings you cannot secure?

A

OOC Log ( Out Of Commission)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Who maintains the Closure Log?

A

EWS(inport) & DCWS(underway)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Who reviews the Closure Log?

A

FM, Duty FM, ADCA, DCA, EDO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Name one side of the Fire Triangle?

A

Oxygen, Fuel, Heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Describe an A, B, C, D fire.

A

A - leaves ashes
B - hazmat, fuel
C - electrical
D - combustible materials

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the flashpoint of JP-5?

A

140 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What are the 4 stages of a fire?

A

Growth, Flashover, Fully Developed, Decay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

If DC Central goes down, where is secondary central located?

A

Repair 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

How many Repair Lockers do we have?

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Where are the repair lockers?

A
2 - by 3M
3 - by ACE4
4 - by Security Dispatch
5 - AFT Mess decks
1A - by trash plant 4
1B - HB2 Port side
1F - between Pipe shop & O2N2 shop
7A - by B&A Crane
7B - by CO's ladder well to bridge
7F - by Wardroom 1 & 2
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Which repair lockers respond to Main Space Fires?

A

Repair 4&5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

What do you use to inventory the kits?

A

AEL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

PKP comes in two sizes, what are they?

A

18 and 27 lb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

What does PKP stand for?

A

Potassium Bicarbonate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

What is the effective range for a 18 lb bottle? 27 lb bottle?

A

19 ft, 21 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

How does PKP extinguish a fire?

A

It interrupts the chemical reaction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

What type of fires does PKP primarily put out?

A

Bravo

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

What is the effective range of a CO2 extinguisher?

A

4-6 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

In continuous operation, how long does the 15 -pound CO2 extinguisher last?

A

40 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

Before you squeeze the lever to release CO2, what should you do?

A

Ground the cylinder to the deck when discharging

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

Why should you ground a CO2 bottle to the deck?

A

To avoid shock from static electricity

38
Q

How does CO2 extinguish a fire?

A

It reduces the concentration of oxygen in the air to the point where combustion stops

39
Q

What are Portable AFFF bottles used for?

A

Grease and small Class Bravo fires

40
Q

What is the distance for a Portable AFFF bottle?

A

15 ft and decreases with use

41
Q

How do you know that the bottle is good?

A

Needle in the gage on top and side of handle should be in the green

42
Q

How much AFFF is in the bottle?

A

2 gallons

43
Q

What are the best woods to use for shoring, plugs, and wedges?

A

Douglas fur and yellow pine

44
Q

Why do we use this type of wood?

A

It expands when it absorbs water

45
Q

What are the two sizes of metal shores?

A

3-5 ft and 6-11 ft

46
Q

What is the vertical load strength of a 3-5 foot metal shore?

A

3ft - 20,000 lbs

5ft - 12,000 lbs

47
Q

What is the vertical load strength of a 6-11 foot metal shore?

A

6ft - 20,000 lbs

11ft - 6,000 lbs

48
Q

Name one type of shoring.

A

I type - direct pressure
K type - triangulation perpendicular
H type - no deck anchorage

49
Q

What is the strongest type of shoring?

A

I type - direct pressure

50
Q

What is the weakest type of shoring?

A

H type - no deck anchorage

51
Q

How many types of Pipe Patches are there?

A

4

52
Q

What are the types of Pipe Patches?

A

Soft, Banding, EWARP, Jubilee

53
Q

Which Pipe Patch can hold up to 100 psi only?

A

Jubilee

54
Q

What is the MAX temperature on a pipe you can apply EWARP?

A

300 degrees

55
Q

What is the Max PSI of the other pipe patches?

A

150 psi

56
Q

What does NFTI stand for?

A

Naval Firefighting Thermal Imager

57
Q

What powers the NFTI?

A

10 AA batteries

58
Q

Is the NiMH battery pack rechargeable?

A

Yes

59
Q

What does EWARP stand for?

A

Emergency Water Activated Repair Patch

60
Q

How do you know the NFTI is fully charged?

A

10bars on the bottom left corner

61
Q

Name 5 kits found in a Repair Locker.

A
  • Shoring
  • Pipe patching
  • Investigator
  • Comms
  • Electrician
62
Q

What does PECU stand for?

A

Portable Exothermic Cutting Unit

63
Q

Where are the PECU’s located?

A

At the Repair Lockers

64
Q

Who operates the PECU’s?

A

Access/Overhaul person

65
Q

What are the cutting rods on the PECU made of?

A

Carbon Steel

66
Q

What size battery does the PECU use?

A

12 volt

67
Q

What are the 2 types of Portable Eductors?

A
  • Derbyshire(replaced S type)

- Perijet

68
Q

What is the primary purpose/use of Eductors?

A

To remove greasy, oily and contaminated water

69
Q

What is the primary use of the P-100?

A

Firefighting

70
Q

What is the secondary use of the P-100?

A

Dewatering

71
Q

How many P-100 pumps do we have onboard?

A

2

72
Q

Where are the P-100’s located?

A
  • HB1, STBD side mooring room

- HB2 in the Admirals P-way under the ladder

73
Q

What cools the P-100 while it is being used?

A

Air

74
Q

What is the maximum lift for the P-100?

A

20 ft

75
Q

What type of fuel does the P-100 use?

A

JP-5

76
Q

What does ESP stand for?

A

Electric Submersible Pump

77
Q

Submersible pumps are not designed for pumping what type of liquids?

A

Gasoline, heavy oils, or hot water

78
Q

What is the maximum static head for the ESP?

A

70 ft

79
Q

When using ESP’s in tandem, which one do you start first?

A

The bottom one

80
Q

What is the purpose of the Ram Fan?

A

To desmoke a space containing explosive gases

81
Q

What powers the Ram Fan?

A

Firemain

82
Q

What safety precautions must be followed prior to energizing the Ram Fan?

A

Ground it

83
Q

What is the maximum number of trunks you can put on the suction side of the Ram Fan?

A

3

84
Q

What is the maximum number of trunks you can put on the discharge side of the Ram Fan?

A

3

85
Q

How are the trunks connected?

A

Latching clamps on the ends of the trunks

86
Q

How many cubic feet per minute will the Ram Fan move?

A

2000 cu. ft/min

87
Q

Where can you use the Box Fan for desmoking operations?

A

Space adjacent to weatherdecks/hanger bay areas

88
Q

What powers the Box Fan?

A

Electricity

89
Q

How much air will the Box Fan move?

A

3200 cu. ft/min

90
Q

Who is in charge of the Repair Locker during a casualty?

A

Locker Leader

91
Q

Who is responsible for handling electrical damage?

A

Repair Electrician

92
Q

Who is in charge of the infected area during a casualty?

A

Team leader