Compounding Flashcards
primary engineering control
(sterile hood/isolator)
ISO class 5
Secondary engineering control
(buffer room, anteroom if it opens a negative pressure buffer room, clean room)
ISO class 7
Anteroom (if opens into a positive pressure)
ISO class 8
HEPA filter
> 99.97% efficient in removing particles as small as 0.3 mircons
-needs to be recertified every 6 months
gloved fingertip test
initially and annually
media filled test
initially and annually
Temperatures
-checked daily
-maintained at 68F (20C)
air sampling
every 6 months
->3 CFU in ISO 5
->5 CFU in ISO 7
->100 CFU in ISO 8
air pressure testing
daily
deactivation and decontamination
2% bleach (Sodium Hypochloride) or peroxide
Cleaning
germicidal detergent
disinfection
sterile 70% isopropyl alcohol
non-aqueous formulations
no later than 6 months (180 days) at room temp
water-containing oral formulations
no later than 14 days when stored at controlled cold temperatures. Store in refrigerator
water-containing topical/dermal and mucosal liquid and semisolid formulations
no later than 30 days at room temp