Company officer Ch 10 Flashcards

1
Q

Pre-incident surveys and fire and life safety code enforcement inspections may both be conducted during a single visit if: (264)

A

required by the department.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which of the following BEST describes the difference between pre-incident surveys and fire and life safety code enforcement inspections? (264)

A

Code inspections ensure buildings are up to code while pre-incident surveys assist fire fighting operations in the future.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which of the following BEST describes why pre-incident surveys should not be conducted alongside inspections? (264)

A

Property management may not be as cooperative.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Building codes: (264)

A

define the type of construction used to build structures.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which type of roof is commonly found on commercial buildings and may also support air-conditioning equipment? (265)

A

Flat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which type of roof has a peak along one edge or in the center? (266)

A

Pitched

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which type of roof may use bowstring trusses as main supporting members? (267)

A

Arched

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which of the following is MOST likely to create a hazard by limiting access into a roof? (267)

A

Tongue and groove construction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which of the following building components BEST describes what should be included in pre-incident surveys? (269)

A

Electrical systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Assigning duties for unit members and ensuring availability of necessary survey documents are processes that should be completed: (269)

A

at the conclusion of the pre-incident survey

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which of the following is MOST likely to be an emergency response consideration for a pre-incident survey? (270)

A

What potential hazards to firefighter safety exist?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which of the following people is MOST likely to schedule the pre-incident survey visit with the owner/occupant? (271)

A

Administrative staff

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Field sketches for survey information records should be made showing the structure’s: (272)

A

size, location, and components

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Which of the following is an area where a company office will MOST likely not be allowed to take photos or videos for a pre-incident survey? (272)

A

Proprietary area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which of the following information about a building BEST describes what should be included in field sketches? (273)

A

The building’s dimensions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Which of the following is the BEST reason to use videography during a pre-incident survey? (274)

A

To show how the facility might appear as someone moves through it

17
Q

Which of the following items should a company officer note the location of while surveying a building’s exterior? (274)

A

Power lines

18
Q

Unless organizational policy dictates otherwise, the starting point for the interior survey is: (275)

A

a matter of personal preference

19
Q

Two basic topic areas of life safety information in a survey include protection and evacuation of occupants, as well as the: (275)

A

protection of firefighters

20
Q

Which of the following NFPA® standards provides guidelines for design and installation of smoke and heat venting equipment? (277)

A

NFPA® 204

21
Q

Automatic roof and wall vents are placed at the _____ point of a roof or wall. (278)

A

highest

22
Q

Monitors with glass sides used in ventilation systems rely on _____ to provide ventilation in case of fire. (278)

A

glass breaking

23
Q

Which of the following systems is a recent advance in HVAC design that introduces thermostatically controlled air into the space through openings in the floor? (279)

A

Underfloor air distribution systems (UFAD)

24
Q

Which of the following fire protection systems, when activated, may potentially restrict movement throughout a structure? (280)

A

Smoke, heat, or alarm activated doors

25
Q

Which of the following is an advantage of pre-incident surveys that includes only essential information? (282)

A

Simple to develop, use, and maintain

26
Q

Which of the following is included in the development process for pre-incident plans? (282)

A

Managing data from multiple plans

27
Q

Which of the following types of facility survey drawings shows side views of structures that depict the number of floors in a building? (282)

A

Elevations

28
Q

The three major tasks of managing pre-incident data include gathering data, entering data into databases, and: (284)

A

keeping data current.