Comfort Flashcards
How many preconditions features are required in the Comfort Concept for Core and Shell certification?
3
To meet the requirements for Feature 74, Exterior Noise Intrusion, a project team must ensure that the avarage sound pressure level from outside noise intrusion does not exceed how many a-weighted decibels (dBA)?
50
Staircase Design of Feature 64, Interior Fitness Circulation, applies to projects with how many floors?
2 to 4
What is required for the performance verification and/or documentation of Feature 77, Olfactory Comfort?
An architectural drawing
What are the source separation methods that can be used to fulfill the requirements of Part 1: Source Separation of Feature 77, Olfactory Comfort?
Negative pressurization, vestibules, hallways, and self-closing doors
What is the maximum allowable reverberation time (RT60) for conference rooms that still meets the requirement of Feature 78, Reverberation Time?
0.6 seconds
What is the maximum noise criteria (NC) for enclosed offices that still meets the requirements of part 2: Mechanical Equipment Sound Levels of Feature 75, Internally Generated Noise?
35
What is the maximum noise criteria (NC) for open office and lobbies that still meets the requirements of part 2: Mechanical Equipment Sound Levels of Feature 75, Internally Generated Noise?
40
What is the maximum noise criteria (NC) for conference rooms and breakout rooms that still meets the requirements of part 2: Mechanical Equipment Sound Levels of Feature 75, Internally Generated Noise?
30
What is the maximum allowable reverberation time (RT60) for open workspaces that still meets the requirement of Feature 78, Reverberation Time?
0.5 seconds