10.01 Definitions
A
- Bulk Merchandising
- Combustible materials in piles greater than 12 ft
- Rubber tires, Group A plastics, flammable liquids, idle pallets greater than 6 ft
- Places of assembly - Greater than 50 people
- School - Ten or more pupils
2
Q
10.02 Extinguishers
A
- Lab showers not greater than 50’ from experimental area
- 30 gallons per minute
- Temps between 70-90o
- Wash Stations
- RED AND WHITE or GREEN AND WHITE sign
- Tested twice annually
3
Q
- 03 General Provisions
(5) Materials Storage
A
- (5) Materials storage
- (b) Permit required for 2,500 or more
- (d) Outside storage - not more than 20’ in height; not less than 25’ from another building
4
Q
- 03 General provisions
(10) Fire lanes
A
- Minimum of 18’
5
Q
10.03.10
Asphalt (Tar) Kettles
A
- Not to exceed 10 MPH
- Not used in buildings under 70’ in height
- Over 70’, must be manned for an hour after operation or until temp hits 315o
- A 20 B:C extinguisher must be used within 30 ft; One additional on roof being covered
- Storage of LPG cylinders on roof tops shall be prohibited
- A pemit must be obtained at least 2 working days prior
6
Q
10.03.16 General Provisions
Use and Storage of Alcohol Based Hand Rub Preparations
A
- Wall mounted or free standing units:
- Max capacity shall be 41 ounces
- Minimum separation between shall be 48”
- Definition: Contains from 60-95% ethanol or isopropanol alcohol
- Storage - In excess of 10 gallons
7
Q
10.13.7
Marking buildings unsafe
A
Interior hazard
8
Q
10.13.7
Marking buildings unsafe
A
Exterior and Interior hazards exist
9
Q
10.13.7
Marking buildings unsafe
A
- Markings shall be at or above 2nd floor level
- Not applied over doors, windows
- 24x24 inches
- Shall bear a date
10
Q
10.08
Hospitals
A
- Head of fire dept shall visit hospitals 4 times each year
11
Q
10.09
Schools
A
- Every student shall be advised of the fire drill procedure within 3 days after entering such school
- 4 fire drills per year
- Records
- Time of drill
- Date of drill
- Weather conditions when occupants were evacuated
- # of occupants evacuated
- Total time of evacuation
- Other Info relevant to drill
12
Q
A
13
Q
10.06
Fumigation an thermal insecticidal fogging
A
- Permit required
- Electricity shut off except circulating fans
- Head of dept must be notifed at least 24 hours before
- Warnings signs
- Red ink on white background
- Letters at least 2” in height
- Watchmen must be useed, except when in a gastight vault or tank
- Thermal insecticidal fogging liquids with a flash point below 100o F shall not be used
14
Q
A
15
Q
- 17 Places of Assembly
- Means of egress
A
- Aisles - Shall not be less than 44” clear width
- 50 or less occupants - no less than 36”