Chlorine (1)
Water Temp: ≥100°F
Water pH: ≤10
Water hardness: as per manufacturer’s rec.
Sanitizer Concentration: 50-99 ppm
Sanitizer contact time: ≥7 seconds
Chlorine (2)
Water Temp: ≥75°F
Water pH: ≤8
Water hardness: as per manufacturer’s rec.
Sanitizer Concentration: 50-99 ppm
Sanitizer contact time: ≥7 seconds
Iodine
Water Temp: 68°F
Water pH: ≤5 or as per manufacturer’s rec.
Water hardness: as per manufacturer’s rec.
Sanitizer Concentration: 12.5 - 25 ppm
Sanitizer contact time: ≥30 seconds
Quats
Water Temp: 75°F
Water pH: as per manufacturer’s rec.
Water hardness: ≤500 ppm or as per manufacturer’s rec.
Sanitizer Concentration: as per manufacturer’s rec.
Sanitizer contact time: ≥30 seconds
How to clean & sanitize
- Scrape/remove all food bits from surface
- wash the surface
- rinse the surface
- sanitize the surface
- all the surface to air-dry
Temp for final sanitizing rinse
≥180°F
Water temp in 3-compartment sink
sink with detergent and water
≥110°F