Chapter 9 - Building Construction and Fire Behavior Flashcards
In what direction does the top chord of a bowstring truss place force on the load-bearing walls?
p. 256
A.) Outward and downward
B.) Inward and upward
C.) Inward and downward
D.) Outward and upward
A.) Outward and downward
After what amount of time of fire exposure can unprotected engineered steel and wooden trusses fail?
p. 255
A.) 10 to 15 minutes
B.) 20 to 25 minutes
C.) 15 to 20 minutes
D.) 5 to 10 minutes
D.) 5 to 10 minutes
Which is the only stage that a fire may not be classified as ventilation-limited?
p. 241
A.) Decay
B.) Incipient
C.) Growth
D.) Fully-developed
B.) Incipient
To some extent, what is the violence of a backdraft dependent upon? p. 240
A.) Amount of fuel present
B.) Degree of fuel/air mixture confinement
C.) Timing of oxygen introduction
D.) Location of the fuel package
B.) Degree of fuel/air mixture confinement
Who is responsible for developing a consensus standard? p. 209
A.) Government offices
B.) Committee of experts
C.) Fire department
D.) Insurance adjustors
B.) Committee of experts
Which zone near the MRI is considered safe for
firefighters to enter with tools and equipment? p. 226
A.) Zone 5
B.) Zone 2
C.) Zone 3
D.) Zone 4
B.) Zone 2
* magnet is always on
Daycares that provide supervision or personal care
services for six or more children older than 2 1/2 years old are placed under which category? p. 222
A.) Institutional
B.) Assembly
C.) Educational
D.) Business
C.) Educational
What must be present for the auxiliary alarm system to be used? p. 229
A.) Proprietary alarm systems
B.) Relay ready alarm systems
C.) Municipal alarm box systems
D.) Central alarm systems
C.) Municipal alarm box systems
What is usually used to determine the classification of the storage occupancy? p. 224
A.) Exterior configuration
B.) Size of interior units
C.) Number of interior units
D.) Interior method of storage
D.) Interior method of storage
Which construction type provides the highest level of protection from fire spread as well as structural collapse?
p. 212
A.) Type IV
B.) Type III
C.) Type I
D.) Type II
C.) Type I
What occurs when a mixture of unburned gases and oxygen comes into contact with an ignition source?
p. 245
A.) Smoke explosion
B.) Flashover
C.) Rollover
D.) Backdraft
A.) Smoke explosion
What color smoke is often present in fires involving foam and plastics?
p. 247
A.) Green
B.) Blue
C.) Gray
D.) Black
D.) Black
What is determined by the construction materials and their resistance to fire exposure? p. 211
A.) Fire protection classification
B.) Exposure rating
C.) Type of leadership structure
D.) Type of building construction
D.) Type of building construction
What is the most effective means of establishing awareness of hazards in commercial and industrial facilities with large fuel loads? p. 247
A.) Preincident surveys
B.) Enforcement inspections
C.) Incident history reviews
D.) Mutual aid training
A.) Preincident surveys
Up to what height must any fire-resistance-rated
separations go when being used in an incidental space? p. 228
A.) Two feet above the top of any protected machinery
B.) Flush with the bottom of the roof decking
C.) Bottom of a fire-resistance rated floor or ceiling above
D.) Six inches above the separating flooring
C.) Bottom of a fire-resistance rated floor or ceiling above
What size hoseline is normally found in a Class II
standpipe and hose system?
p. 231
A.) 1 1/2-inch (38 mm)
B.) 2 1/2-inch (65 mm)
C.) 2-inch (50 mm)
D.) 1-inch (25 mm)
A.) 1 1/2-inch (38 mm)
Which NFPA standard is the major model building code in the United States? p. 211
A.) NFPA 4000
B.) NFPA 5000
C.) NFPA 6000
D.) NFPA 3000
B.) NFPA 5000
Which is NOT a correct statement about a
ventilation-limited fire situation? p. 236
A.) If no other source of oxygen exists, the compartment will fill with black smoke and slowly cooling gases
B.) The pressure outside the compartment is higher than the pressure inside the compartment
C.) Due to a pressure differential, any ventilation to the outside provides a flow path for the hot gases
D.) The characteristics in the fuel and fuel loading today’s typical fires will cause fires to become ventilation-limited quickly
B.) The pressure outside the compartment is higher than the pressure inside the compartment
Which is NOT a correct statement? p. 254
A.) Legacy construction assemblies commonly fail over a small area
B.) Plastic continuous roof vents can melt, self-seal, and change the ventilation profile and fire conditions in the structure below
C.) Sight, sound, and touch indicators help the firefighter spot impending collapse
D.) Data and images from thermal imagers do not reliably indicate impending collapse
C.) Sight, sound, and touch indicators help the firefighter spot impending collapse
Since what year has an NFPA analysis of fires in
residential occupancies indicated a steady decline in fires in manufactured homes?
p. 216
A.) 1984
B.) 1972
C.) 1980
D.) 1976
C.) 1980
What causes the hot gas layer within the fire compartment to spread downward?
p. 234
A.) Higher pressure
B.) Higher temperatures
C.) Lower pressure
D.) Lower temperatures
A.) Higher pressure
During which stage does a backdraft occur? p. 240
A.) Decay
B.) Fully developed
C.) Growth
D.) Incipient
A.) Decay
Which class of fuel is the most common type of fuel found in structures?
p. 247
A.) Class A
B.) Class B
C.) Class C
D.) Class D
A.) Class A
What must be used to classify the residential board and care occupancy as a whole?
p. 223
A.) Resident posing the most significant risk
B.) Level of care given to the occupants
C.) Total number of residents present
D.) Building and floor configuration
A.) Resident posing the most significant risk
What is the minimum number of patients that are provided care on an outpatient basis at an ambulatory health care occupancy? p. 223
A.) Four
B.) Five
C.) Seven
D.) Six
A.) Four
Which is NOT a correct statement about the flow path in a structure fire? p. 242
A.) The products of combustion flow toward the fire and away from the low pressure opening
B.) The air flow is always unidirectional due to pressure differences where the ambient air flows toward the seat of the fire and reacts with the fuel
C.) The flow path is composed of the hot exhaust flow out and ambient air flow in
D.) The floor plan and openings within the structure determine the available flow path
A.) The products of combustion flow toward the fire and away from the low pressure opening
By which method is heat transferred to the walls, ceiling, floors, and objects in the compartment when a fire is confined within the compartment?
p. 241
A.) Conduction
B.) Radiation
C.) Convection
D.) Reduction
B.) Radiation
Before what year were bowstring truss roofs one of the most common design types for large commercial and industrial structures? p. 256
A.) 1965
B.) 1960
C.) 1975
D.) 1970
B.) 1960
Per the ICC, what designation is given to prisons and detention facilities with more than 5 people under restraint? p. 220
A.) Group I-4
B.) Group I-2
C.) Group I-1
D.) Group I-3
D.) Group I-3
What is the appearance of isolated flames in the hot gas layer sometimes an immediate indicator of? p. 234
A.) Flashover
B.) Smoke explosion
C.) Flameover
D.) Backdraft
A.) Flashover
The use of which material has dramatically increased the fuel load in all types of occupancies? p. 252
A.) Plastics
B.) Steel
C.) Wood
D.) Masonry
A.) Plastics
What type of construction can a Type V building be mistaken for? p. 214
A.) Type VI
B.) Type III
C.) Type IV
D.) Type II
B.) Type III