According to the Rules and Regulations, the approval of tools, appliances and equipment and their manner of care and use lies with?
Fire Chief
According to the Manual of Operation, the final approval for modification of apparatus is required from ____.
Administrative Operations Chief Deputy
According to the Manual of Operation, all requests for alteration, addition, or deletion of communication equipment shall be forwarded, through channels, to?
Bureau Commander, Support Services
According to the Manual of Operation, requests for alterations, improvements, addition or installation to any Fire Department facility shall be submitted and forwarded to ____ who will review and approve or disapprove the request.
Respective Bureau Commander
According to the Manual of Operation, approval of modifications and alterations of apparatus are required by?
All three
Bureau Commander, Emergency Services Bureau
Bureau Commander, Training and Support Bureaa
Administrative Operations Chief Deputy
According to the Manual of Operation, members shall not change or alter the arrangements of firefighting equipment on apparatus, nor otherwise rearrange the system in effect without approval of?
Fire Chief
According to Training Bulletin #106 LCES and Watch-Outs for Structure Fires,” which of the following statements is not true regarding mezzanines:
a.Mezzanines are often constructed illegally
**b. Mezzanines are often found inside a rolling steel doorway
c. Mezzanines have been recognized as significant threats to the safety of firefighters
d. Realizing you are working underneath a mezzanine is one of the fourteen interior firefighting “watch-outs”
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” rooms may contain mezzanines when the clear height above and below the mezzanine is not less than _____, with no more than ____level (s) of mezzanines in a room. The aggregate area of mezzanines within a room shall not exceed____ the are of the room in which they are located
7 feet
2 levels
one-third
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” two exits shall be provided from mezzanines having an occupant load of more than ___ or when the area of the mezzanine exceeds ____ square feet, whichever is more restrictive.
Ten
2000
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” the clear height above or below a mezzanine floor construction shall be not less than _____.
7 feet
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” all portions of a mezzanine shall be open to the room in which it is located. The side of the mezzanine which is open to the room shall be unobstructed except
for columns, posts, and protective walls, or railings not more than__ in height
42
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” when the total area of any such mezzanine floor exceeds ____ percent of the total floor area in that room, it shall be considered as constituting an story in the building.
33-1/3
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” the fire-resistive time period for unenclosed mezzanines where all portions of the mezzanine are open to the room in which it is located need not exceed:
1 hour
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” there shall not be more that ___ level (s) of mezzanines in a room.
2
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” the number of mezzanines allowed within a room is:
there is no limitation
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” the aggregate area of a mezzanine withing a room shall not exceed_____ the area of the room in which they are located.
one-third
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” mezzanines having two or more exits need not open into the story in which they are located, provided at least one of the exits gives direct access to any of the following except:
a. protected exit corridor
b.an exit court
c.enclosed exit stairway
d exterior exit
e there are no exceptions all are allowed
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” in industrial facilities, mezzanines used for control equipment may be glazed (windows) on ____ sides
all sides
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” partitioning a mezzanine may be installed provided aggregated floor area of enclosed space does not exceed:
10% of area of the mezzanine or have an occupant load exceeding 10, whichever is greater.
According to Training Bulletin #54, “Hazardous Illegal Mezzanines,” a mezzanine floor shall be considered an additional story in the building when the mezzanine floor exceeds a certain minimum percentage of the total floor area. What is the minimum percentage?
33 -1/3
According to the Manual of Operation, “Volume 6, Fire Prevention / General ,” the purpose of the station fire prevention program is?
obtain complete coverage of the city
According to the Manual of Operation, “ Volume 6, Fire Prevention/General,” all of the following occupancies or conditions will normally be inspected by fire station responsibility except:
a. Group A occupancies with an occupant load of less than 100 persons
b. Group B occupancies less than 5 stories in height and less than 40,000 square feet total on all floors
c. Group H (repair garage) occupancies
d. Group R-1 occupancies less than 6 stories in height
According to the Manual of Operation, “ Volume 6, Fire Prevention/General,” the purpose of the station fire prevention is ?
obtain complete coverage of the city
According to the Manual of Operation, “ Volume 6, Fire Prevention/General,” all matters relating to fire prevention at the station level are under the direct supervision of the line officers concerned. When conditions are found which require special information, technical knowledge or change, it is the responsibility of the line officers to secure the necessary information from: