Cap 14 Fire And Smoke Detection Flashcards
The level of fire and smoke detection depends on the accessibiilty of the comportment
Two types of smoke detectors
~optical smoke»_space;when there is smoke the light source is reflected to the sensor ,triggering smoke detection signal
~ionising smoke detector»small quantity of radioactive material held in the ionising chamber,the material emits alpha particles which ionise the air in the chamber,this allows a small current to flow between two plates in the detector,smoke absorb alpa particles ,so the ionising stops and so the current flow stops,triggering the smoke signal
Fire detection and protection
Is provided in bleed air systems
Over heat protection are also provided in the wheels bay
Fire detection is provided in two key areas
~engine bays
~cargo compartment
Engine bay fire zones
~zone 1»_space;main engine accessories,most sensitive to fire .requires fire detection and extinguisher systems
~zone 2»the compressor are
~zone 3»combustion and turbine section
Each zone is separated by a fireproof bulkhead
Alternatively there may be just COOL ZONE comprising the compressor and the fan, and HOT ZONE comprising the combustor and the turbine section
Apu fire
Its automatically shut down if it detects fire,also stop if the vibration or heat is excessive
Fire detection
~continuous loop engine detection system(know as fire wire):
Comprises a nickel core surrounded by a coating of eutectic salt.
If temperature rises the resistance of the slat goes down,flow current increases through the nickel core.if the units detects a drop ion resistance and if also the if the capacitance changes it triggers the signal of fire
Loop A and loop B both need to detect fire or overheat before warning is triggered,if one is faulty the faulty can be turned off to restore fire detection capability
~gas (helium) filled detectors:
Most used is the systron donner
Comprises two gas filled loops and a responder unit incorporating two pressure switches
Core contains helium gas pressurised to 7psi
If loop breaks ,pressure will drop ,causing a fault warning.
If fire is present on an intact loops ,pressure rises and triggers the fire alarm
~bi metallic overheat sesnor:
provides spot rather than area protection,when it heats up it stretches making the two contractor to close,if it cools it contracts making the contacts to separate
Fire warning
Will indicate: ~fire master caution ~fire warining bell ~associated eng fire ~illuminates extinguisher operating handle ~displays warning on EICAS or ECAM
Engine fire suppression system on Boeing 737
~pulling the fire handle»
~closes wing spar shut off valve,isolating engine bay from fuel system ~closes the bleed air PRSOV ~shuts off hydraulic pump ~isolate hyd supply ~isolates electrical genrator ~arms the extinguisher ~closes the apu shit off valve
Engine fire suppression
~2 fire extinguisher bottle per eng
Cargo compartment extinguishers
`extinguishing agent HALON pressurised by NITROGEN
Toilet comportment fire extinguishers
~protected by automated extinguishers
~fires into waste bin and under sink area when heat is detected.
Freon or BCF extinguishant