CAL/OSHA Flashcards
You must obtain a DOSH permit for construction of trenches or excavations ____ or deeper that owners must enter
5 feet
Per Cal/OSHA , one story is how many feet ?
12 feet
An employer must make medical records/ exposures available within how many days of a request by the worker ?
15 days
Ground areas within how many feet of buildings under construction must be kept reasonably free from irregularities ?
6 feet
The face of a pile of cement bags more than ____ft high must be tapered back.
5 feet
LUmber piles must not be higher than ____ ft if lumber is handled manually, or _____ ft if handled with equipment
16 feet = manually
20 feet = equipment
Employers must monitor noise and administer hearing conservation program when noise exposure is what or more ?
85 dB or more
A confined space is defined as an area where:
- Existing ventilation does not remove air contaminants or replace oxygen deficient air AND
- Ready access, exit, or removal of a suddenly-disabled employee is difficult.
Ladder rungs must be at least ____ inches long and spaced 12 inches apart
11.5
Cleat (straight ) ladders may not be longer than ____ feet
30 feet
Metal Extension ladders may not be taller than ____ feet
48 feet
Extension ladder overlapping sections must be at least ___% of the working length
10%
When digging 4 feet or more you must:
- Provide a safe way for entry and egress ( ladders) within 25 feet of any work area. Minimum of 50 feet at a large site.
When digging 5 feet or more you must:
- Obtain permit from DOSH before starting excavation
- Shore, bench, slope or use equivalent methods to protect workers.
- Must deposit excavated materials at least 2 FEET from the edge of excavation.
When digging 6 feet ( and 30” wide ) or more you must :
Install crossings with standard guardrails and toeboards
When excavating how many feet or more must protective systems be designed by a registered engineer ?
20 feet or more
Standard shoring system consist of:
- Solid plywood sheathing at least 2” thick
- Plywood at least 1 1/8” thick
- Wood uprights at least 2” x 8” ( spaced maximum 8 feet ) and
- Wood braces and diagonal shores at least 4”x4”
Do not slope a trench greater than ___ from vertical
15˚
What is the longest standard length of a scaffold plank?
10 feet
On a 120V circuit, what color is the (protective) ground wire?
Green
What is the minimum distance apart that acetylene and oxygen cylinders must be stored?
20 feet
An alternative is a noncombustible barrier between the cylinders at least 5 feet high with a fire-resistance rating of at least 1/2 hour.
Which of the following is the best choice for hoisting a full gas cylinder?
A. Manila rope sling
B. synthetic rope sling
C. wire rope sling
D. a cradle, net, or skip box
D. Cradle, net, or skip box.
A dry chemical or carbon dioxide fire extinguisher rated at least _____ must be kept near operations where bottled fuel gases are being used.
10:BC
No more than _____ of paints, solvents, and chemicals may be stored in a room unless an approved safety storage cabinet is present.
25 gallons
For a vertical safety lifeline, what is the MINIMUM breaking strength after it has been attached to the anchorage point?
5000 lbs
If you are writing an IIPP for your jobsite, which of the following is a highly recommended reference
Cal/OSHA IIPP e-tool
The shield of a shielded wire:
Should be connected to ground
On a jobsite, if you find yourself raising your voice to speak to others at a distance of _____ OR LESS, you should wear hearing protection.
5 feet
When working in or within _____ of an open hoistway where you might be able to fall more than _____, you must wear fall-arrest equipment, and lanyards must be attached to lifelines at all times.
6 feet……. 6 feet
A worker is using an electric meter to check a live circuit. Which of the leads is removed from the circuit first ?
Hot
During hoisting operations, the signaler extends both arms straight out and to the side, with palms down and hands moving rapidly right and left. What is the signaler trying to say?
Emergency Stop
When making a vertical lift with eye bolt(s), which of the following is the recommended procedure?
Make a completely vertical lift on the eye bolt(s)
When hoisting two or more pieces of material more than _____ long, double slings must be used.
12 feet
With reference to lifting operations, the term “ultimate strength” refers to what?
The average load or force at which the product fails or no longer supports the load.
When inspecting Manila rope, if the outer surface and/or inner side of strands is blackened or rust-colored, you should suspect:
Damage from acids or caustics
According to the Construction Safety Orders, a CONSTRUCTION passenger elevator for hoisting workers must be installed in any building or structure designed to be _____ feet or more in height above or _____feet in depth below ground level when it is completed.
60 feet… 48 feet