AW 139 Hydraulics Flashcards
When is the Hydraulic Utilities Shut-Off Valve (SOV) closed?
When there is an oil leak (automatically when there is an oil leak)
When setting the Shut-Off Valve (SOV) 1 switch on the Hydraulic Control Panel to CLOSE, what cautions are displayed?
1 SERVO, 1 HYD OIL PRESS
When setting the Shut-Off Valve (SOV) 2 switch on the Hydraulic Control Panel to CLOSE, what cautions are displayed?
2 SERVO, 2 HYD OIL PRESS
In case of failure of Hydraulic Pump #2, what cautions are displayed?
2 HYD PUMP
In case of failure of Hydraulic Pump No.1, what cautions are displayed?
1 HYD PUMP, 1 SERVO, 1 HYD OIL PRESS, EMERG LDG PRESS
What is the effective recovering action after receiving a HYD UTIL PRESS caution?
SOV 1 and SOV 2 switches on the Hydraulic Control Panel are ineffective (are not relevant to recovery the malfunction)
What would be the pressure indication on the Hydraulic System #1, with the Hydraulic Control Panel Shut-Off Valve (SOV) #1 set to CLOSE ?
About 207 bar
What condition will allow the Shut-Off Valve (SOV) 1 to CLOSE?
Tail Rotor Shut-Off Valve (TRSOV) valve is open
What action should be carried out after a 2 HYD PUMP caution?
Continue flight
What is the main function of the Hydraulic Electric Pump?
Provides flight controls freedom of movement check
Which caution could be displayed with the 1 SERVO caution?
EMER LDG PRESS in case of loss of pressure on the system
What is the recovering action in case of 2 SERVO caution?
Land as soon as practicable
Which of the following conditions could illuminate the 2 SERVO caution ?
The control valve in a servoactuator is jammed or loss of pressure on the system
After setting the SOV switch on the Hydraulic Control Panel to No.1 CLOSE, what cautions are displayed?
1 SERVO, 1 HYD OIL PRESS
If the SOV 1 switch on the Hydraulic Control Panel has been set to CLOSE and there is a subsequent drop of pressure on system 2:
The SOV switch is automatically reset
Pressure on system 1 is reinstated
On PCM 1 the utilities shut-off valve is closed by the following microswitch(es):
MIN (22%)
The pressure transducers in the PCM is located:
Before F/C shut-off valve, before utilities shut-off valve
TRSOV in the Hydraulic Circuit 2 is closed by the following microswitch(es) in the PCM 2 reservoir:
LOW 2 (28%)
On PCM 1 the utilities shutt-off valve is closed by the following microswitch(es):
MIN (22%)
LOW 2 (28%) microswitch in the PCM 2 provides the following:
Opens utilities shut-off, closes TRSOV
The pressure transducer in the PCM is located:
Before F/C shut-off valve, before utilities shut-off valve
In case of 2 HYD PUMP caution:
Continue flight
In case of 1 HYD PUMP caution:
Land as soon as practicable
In case of 4 HYD PUMP caution:
Continue flight