AW 139 ECS Flashcards
On the windscreen wiper/washer control panel, the DUAL and FAST modes are set and the co-pilot WIPER momentary switch pressed
c. Both the wipers operate at a frequency of 90 cycles per minute
The WINDSHIELD WASHER mode has precedence against the following operational
b. SLOW/FAST, SINGLE/DUAL and WIPER modes
The washing cycle engages either the pilot and co-pilot systems according to
a. The light/heavy washing cycle
The wipers park automatically
a. When the rotary switch is set to OFF once they reach the parking position
When the caution 1 PITOT HEAT OFF is displayed:
a. The Pitot no. 1 is not activate with the OAT less than 4ºC
The PITOT probe
a. Embedes both the static pressure and the dynamic pressure source
The folowing message 1-2 PITOT FAIL is displayed
c. When both the Pitot heating systems are faulty
The current monitor purpose is
b. To provide the pitot heat current and detect when it is below 0.6A
The advisory message 1 PITOT HEAT ON is proposed when
c. The Pitot no.1 is set to ON
The outside ram air for the cockpit in the ventilation system enters
a. Through intakes positioned on the lower side of the nose section
The flapper valve switch when selected
a. Opens or closed the relative flapper valve and controls the fan